Zones; Long Term Event History - Directed Electronics AM5 Installation Manual

Security system
Hide thumbs Also See for AM5:
Table of Contents

Advertisement

zones

Zone
Trigger Type
Number
1
Instant trigger
2
Multiplexed input
3
Two-stage, progresses from warning
to full alarm
4
Multiplexed
5
Two-stage (similar to zone 3)
N N O O T T E E : : The Warn Away
®
response do not report on the LED.

long term event history

The control module will store the last 2 triggers (zone numbers) in memory. To access
the event history use the following procedure.
1. Turn the ignition switch off and press and hold the integrated LED/Valet
2. While holding the integrated LED/Valet
3. Release the integrated LED/Valet
4. Within 5-seconds, press and release the integrated LED/Valet
The LED will flash in groups indicating the last two zones reported triggered. For
example, if zone 2 and 3 were the last two zones to be triggered, the LED will flash
two times followed by a pause and then flash three times followed by a pause.
© 2003 directed electronics, inc.
Input Description
Hood and/or trunk pin switches.
Heavy impact from on-board
Doublegurard
shock sensor.
®
Door switch circuit.
Optional sensor, Inputs shorter than
0.8 seconds will trigger Warn Away
response, while inputs longer than
0.8 seconds will instantly trigger full
alarm.
Ignition input.
switch turn the ignition On.
®
switch.
®
®
switch.
®
®
switch.
21