SECTION 1—GENERAL GUIDELINES
DO NOT climb, go up or down ramps or traverse slopes greater than 7°.
DO NOT attempt to move up or down an incline with a water, ice or oil film.
DO NOT attempt to drive over curbs or obstacles. Doing so may cause your wheelchair 
to turn over and cause bodily harm or damage to the chair.
DO NOT leave the power button in the On position when entering or exiting your 
wheelchair.
DO NOT stand on the frame of the wheelchair.
Limited Clearance Between Footboard and Caster ‐ The user's feet MUST remaincentered 
on the footboard, away from the footboard sides, while operating the wheelchair. If the 
user's feet are allowed to rest off the side of the footboard they may come in contact with 
the caster possibly resulting in injury.
DO NOT stand on the flip‐up footboard, otherwise damage may occur. When getting in 
or out of the wheelchair, make sure that the flip‐up footboard is in the upward position.
DO NOT stand on the front riggings, otherwise damage may occur. When getting in or 
out of the wheelchair, make sure that the footplates on the front riggings are in the 
upward position or moved out of the way.
ALWAYS wear your seat positioning strap. The seat positioning strap is a positioning belt 
only. It is not designed for use as a safety device withstanding high stress loads such as 
auto or aircraft safety belts. If signs of wear appear, belt MUST be replaced immediately.
Make sure the detent balls of the quick‐release pin are fully released beyond the outer 
edge of the tube before operating the wheelchair. Otherwise, injury and/or damage may 
result.
Keep detent balls clean.
Before performing any maintenance, adjustment or service verify that On/Off switch on 
the joystick is in the Off position.
Avoid storage or use near external flame or combustible products.

Accessories

Extreme care should be exercised when using oxygen in close proximity to electric circuits 
and other combustible materials. Contact your oxygen supplier for instruction in the use 
of oxygen.
Invacare products are specifically designed and manufactured for use in conjunction with 
Invacare accessories. Accessories designed by other manufacturers have not been tested 
by Invacare and are not recommended for use with Invacare products.