No.
Part name
Pulse
1. Detachment
modulating
1) Perform work of item 1 of
valve coil
2) Turn the coil clockwise (counterclockwise) by 90
2. Attachment
1) Set take-out part of the lead wire of coil to the
2) Turn the coil by 90 degrees, set surely the
Fan guard
1. Detachment
1) Perform work of item 1 of
2) Remove the front cabinet, and put it down so
3) Remove the hooking claws by pushing minus
2. Attachment
1) Insert claw of the fan guard in the hole of the
Procedure
degrees, and remove coil from the pulse modu-
lating valve.
coil inserting position of the pulse modulating
valve, and attach the coil.
concave part at lower part of the coil to the
positioning hole of the pulse modulating valve,
and then fix the coil.
The pulse modulating valve has A room
side and B room side. After mounting it,
check that coil at B room side (Red
marking is marked on the pulse modulat-
ing valve.) is connected to CN13 of the
control board assembly.
that fan guard side directs downward.
Perform work on a corrugated cardboard,
cloth, etc. to prevent flaw to the product.
screwdriver according to the arrow mark in the
right figure, and remove the fan guard.
front cabinet. Push the hooking claws (10
positions) by hands and fix the claws.
All the attaching works have completed.
Check that all the hooking claws are fixed
to the specified positions.
, and
,
,
.
Coil inserting
, and
.
– 76 –
Remarks
Take-out part
of lead wire
Notch
position
Coil inserting
Positioning
position
hole
Minus screwdriver
Hooking claw
Coil fix
position