OPTIONAL PARTS

14-1. AIR CLEANING FILTER
AIR CLEANING FILTER removes fine dust of 0.01 micron from air by means of static electricity.
Normal life of AIR CLEANING FILTER is 4 months. However, when it becomes dirty, replace it as soon as possible.
Clogged AIR CLEANING FILTER may reduce the air conditioner capacity or cause frost on the air outlet.
DO NOT reuse AIR CLEANING FILTER even if it is washed.
DO NOT remove or attach AIR CLEANING FILTER during unit operation.
MSZ-G09SV -
MSZ-G09SV -

14-2. DEODORIZING FILTER

DEODORIZING FILTER removes ammonia and hydrogen sulfide emitted from tobacco, and odor of pets.
Clean DEODORIZING FILTER every two weeks. If the filter is particularly dirty, clean the filter more often.
For cleaning, soak the filter in warm water for a while, and then wash and rinse it. Dry the filter in the shade thoroughly.
When the filter color is still dark even after cleaning, replace the filter with a new one.
Replace the filter at least once a year.
MSZ-G09SV -
MSZ-G09SV -
DEODORIZING FILTER and AIR CLEANING FILTER can be attached on either side.