Mitsubishi Electric MSZ-G09SV-E1 Service Manual page 15

Split-type, heat pump air conditioners wireless type
Hide thumbs Also See for MSZ-G09SV-E1:
Table of Contents

Advertisement

MAX. REFRIGERANT PIPING LENGTH
Model
MSZ-G09SV -
E1
MUZ-G09SV -
E1
MSZ-G09SV -
E2
MUZ-G09SV -
E2
MSZ-G12SV -
E1
MUZ-G12SV -
E1
MSZ-G12SV -
E2
MUZ-G12SV -
E2
MAX. HEIGHT DIFFERENCE
Indoor
unit
w Max. Height
difference 8m
(MSZ-G09SV )
w Max. Height
difference 10m
(MSZ-G12SV )
ADDITIONAL REFRIGERANT CHARGE (R22:g)
Outdoor unit
Model
precharged
MSZ-G09SV -
E1
MUZ-G09SV -
E1
MSZ-G09SV -
E2
MUZ-G09SV -
E2
MSZ-G12SV -
E1
MUZ-G12SV -
E1
MSZ-G12SV -
E2
MUZ-G12SV -
E2
Refrigerant piping
Max. length : m
A
12
15
Refrigerant Piping
Max. length
w Height difference should be within
8m(MSZ-G09SV ) / 10m(MSZ-G12SV )
regardless of which unit,
indoor or outdoor position is high.
5m
6m
750
0
30
0
30
1100
Piping size O.D : mm
Liquid
Gas
9.52
6.35
12.7
A
Refrigerant piping length (one way)
7m
8m
9m
10m
60
90
120
150
60
90
120
150
Calculation : Xg=30g/mo(Refrigerant piping length(m) - 5)
15
Length of connecting pipe : m
Indoor unit
Gas 0.43
Liquid 0.5
Outdoor unit
11m
12m
13m
180
210
180
210
240
Outdoor unit
14m
15m
270
300