PRODUCT FEATURES
AVFLST42 CONTROLS
LED Switches
Control Module
Thermocouple Module
Figure 1. AVFLST42 Controls (Control Access Door Shown Open)
Monessen • AVFLST42 Installation Instructions • 4118-900 Rev. B • 05/2020
6
Aux Module
GAS SPECIFICATIONS & ORIFICE SIZE
MAX. INPUT
MODEL
FUEL
AVFLST42NIP
NAT.
AVFLST42PIP
LP.
NOTE: For LP models an external regulator is required
to reduce supply pressure to a maximum of 13" w.c.
GAS PRESSURES
Inlet Minimum
Inlet Maximum
Regulator Pressure
Setting
Pilot Regulator
AVFLST Vent Free Fireplace
MIN. INPUT
ORIFICE
(BTU/h)
(BTU/h)
37,000
24,500
2.20 mm
36,000
28,500
NATURAL
PROPANE (LP)
5.0" w.c.
11.0" w.c.
10.5" w.c.
13.0" w.c.
3.5" w.c.
10" w.c.
3.5" w.c.
—
SIZE
#55