Listing And Code Approvals; Model Specifications; Step-By-Step Installation - Dimplex BFSL33 Installation Manual

Fireplace
Hide thumbs Also See for BFSL33:
Table of Contents

Advertisement

LISTING AND CODE APPROVALS

The BF series fireplaces have been tested in accordance with the UL 2021 and
CSA C22.2 No. 46 standards for fixed and location-dedicated electric room
heaters.

MODEL SPECIFICATIONS

Rated
Voltage
Power
(Volts)
(Watts)
120/120/
8/1223/
208/240
1823/2423
!
NOTE: Power ratings shown include LED lights and motors (10 watts)
WARNING: The installation of the fireplace unit must comply with the appli-
cable Local and/or National Electrical Codes and utility requirements. This
installation should be entrusted to duly qualified personnel where required
by law.

STEP-BY-STEP INSTALLATION

!
NOTE: Please read all instructions before installing .
1.
Rough in framing opening following the recommended dimensions located
in Section A: Framing Dimensions.
2.
Allow 8" (20.3 cm) of service cable for connecting power supply wire to
junction box on fireplace when installing before finishing wall. Allow up to
4' (121.9 cm) of service cable for connecting power supply wire to junction
box on fireplace when installing after finishing wall. Remove the outer
jacket and strip the individual conductors ½" (1.3 cm) from the end.
3.
Loosen the screw securing the junction box cover and remove the cover.
4.
Remove knockouts, if necessary, or use the provided cable clamp.
5.
Place unit in position in the framed opening, level with shims if necessary
and attach unit to frame using mounting flanges provided (Figure 3).
6.
Unit is factory wired for 208/240V power supply. If 120V operation is
required, slide the switch and reconfigure the wiring (Section C). Wires L1,
L2, N & G are attached to the rear of the junction box cable clamp for easy
access.
!
NOTE: If wiring unit to operate with NO heat a dedicated circuit may not
be required.
7.
Wire a dedicated, properly fused circuit with a 15amp rating for the appro-
priate voltage (120V, 208/240V). See Section C for factory setting wiring.
8.
Make wall switch and or wall mounted thermostat connections as outlined
in Section D.
9.
Place all connectors inside the unit and secure the junction box cover to
unit. Ensure that the cable clamp grips only the jacket of service cable,
thermostat and if applicable wall switch lines.
Remote
Wall
Control
Thermostat
3 Stage
Optional
AMPS
No Heat
120
120 Volt
Volt
0.07A
10.2A
240
208 Volt
Volt
8.7A
10.1A
3