Dimplex BFSL33 Installation Manual page 16

Fireplace
Hide thumbs Also See for BFSL33:
Table of Contents

Advertisement

unit.
!
NOTE: The following installation instructions are for a single pole thermo-
stat.
1.
Loosen the screw securing the junction box and remove the cover.
2.
Remove the knockouts (if necessary) or use the provided cable clamp.
3.
Pull out the three wires marked 1, 2, and G (red, red, and green).
4.
Remove the wire connector and separate the wires marked 1 & 2.
5.
Connect the 1 wire (red) from the unit to the Neutral (white) wire from the
wall thermostat box by using a wire connector (not supplied).
6.
Connect the other end of the Neutral (white) wire from the thermostat wall
box to the red wire from the wall thermostat.
7.
Connect the 2 wire (red) from the unit to the black wire from the thermo-
stat wall box by using a wire connector (not supplied).
8.
Connect the other end of the black wire from the thermostat wall box to
the black wire from the wall thermostat.
9.
Connect the Ground wire (green) from the unit to the Ground (green) wire
from the thermostat wall box by using a wire connector (not supplied).
10.
Connect the other end of the Ground wire (green) to the thermostat wall
box ground screw.
11.
Ensure that all connections are tight.
12.
Insert all the wiring of the wall mounted thermostat into the wall box.
13.
Insert all the wiring back into the unit and secure with a cable clamp.
16
BLACK
RED
GROUND
1
2
GROUND
G
1
2
GROUND
G
BLACK
BLACK WIRE
RED
WHITE WIRE
GROUND
SCREW
GROUND
!
NOTE: This only illustrates
thermostat connection, see
previous sections for main
power connection instruc-
tions.
www.dimplex.com