Listing And Code Approvals; Model Specifications - Dimplex BFSL33 Installation Manual

Dimplex bf series fireplace installation guide
Hide thumbs Also See for BFSL33:
Table of Contents

Advertisement

LISTING ANd COdE APPROvALS

The BF series fireplaces have been tested in accordance with the UL 2021 and
CSA C22.2 No. 46 standards for fixed and location-dedicated electric room
heaters.

MOdEL SPECIFICATIONS

Rated
Voltage
Power
Volts
Watts
120/120/
8/1223/
208/240
1823/2423
!
NOTE: Power ratings shown include LEd lights and motors (10 watts)
WARNING: The installation of the fireplace unit must comply with the ap-
plicable Local and/or National Electrical Codes and utility requirements.
This installation should be entrusted to duly qualified personnel where
required by law.
STEP-bY-STEP INSTALLATION
!
(
NOTE: Please read all instructions before installing)
1.
Rough in framing opening following the recommended dimensions located
in (Section A: Framing).
2.
Allow 8" of service cable for connecting power supply wire to junction box
on fireplace when installing before finishing wall. Allow up to 4 feet of
service cable for connecting power supply wire to junction box on fireplace
when installing after finishing wall. Remove the outer jacket and strip the
individual conductors ½" from the end.
3.
Loosen the screw securing the junction box cover and remove the cover.
4.
Remove knockouts if necessary or use the provided cable clamp.
5.
Place unit in position in the framed opening, level with shims if necessary
and attach unit to frame using mounting flanges provided (see figure 3 on
page 3).
6.
Unit is factory wired for 208/240 volt power supply
on page 6). If 120 volt operation is required, slide the switch and
reconfigure the wiring (Section C). Wires L1, L2, N & G are at-
tached to the rear of the junction box cable clamp for easy access.
!
NOTE: If wiring unit to operate with NO heat a dedicated circuit may
not be required.
7.
Wire a dedicated, properly fused circuit with a 15amp rating for the appro-
priate voltage (120, 208/240). (see Section C for factory setting wiring)
8.
Make wall switch and or wall mounted thermostat connections as outlined
in Section D.
9.
Place all connectors inside the unit and secure the junction box cover to
unit. Ensure that the cable clamp grips only the jacket of service cable,
thermostat and if applicable wall switch lines.
Remote
Wall
Control
Thermostat
Std.
Option
AMPS
AMPS
No Heat
120
120 Volt
Volt
0.07
10.2
(see figure 1
AMPS
AMPS
208
240
Volt
Volt
8.7
10.1
3

Advertisement

Table of Contents
loading

Table of Contents