LISTING AND CODE APPROVALS

The BF series fireplaces have been tested in accordance with the UL 2021 and CSA C22.2 No. 46 standards for fixed and
location-dedicated electric room heaters.

MODEL SPECIFICATIONS

Model
Description
Number
BF45DXP
45" Deluxe
BF39DXP
39" Deluxe
BF39STP
39" Standard
BF33DXP
33" Deluxe
BF33STP
33" Standard
!
NOTE: Power ratings shown include the light bulbs and motors (275 watts)
The installation of the fireplace unit must comply with the applicable Local and/or National Electrical Codes and utility require-
ments. This installation should be entrusted to duly qualified personnel where required by law.

STEP-BY-STEP INSTALLATION

!
NOTE: Please read all instructions before installing.
1. Rough in framing opening following the recommended dimensions located in Section A: Framing Dimensions.
2. Allow 8" (20.3 cm) of service cable for connecting power supply wire to junction box on fireplace when installing before
finishing wall. Allow up to 4' (121.9 cm) of service cable for connecting power supply wire to junction box on fireplace
when installing after finishing wall. Remove the outer jacket and strip the individual conductors ½" (1.3 cm) from the end.
3. Loosen the screw securing the junction box cover and remove the cover.
4. Remove knockouts, if necessary, or use the provided cable clamp.
5. Place unit in position in the framed opening, level with shims if necessary and attach unit to frame using mounting flanges
provided (Figure 2).
6. Unit is factory wired for 208/240V power supply. If 120V operation is required, slide the switch and reconfigure the wiring
(Section C). Wires L1, L2, N & G are attached to the rear of the junction box cable clamp for easy access.
!
NOTE: If wiring unit to operate with NO heat a dedicated circuit may not be required.
7. Wire a dedicated, properly fused circuit with a 15amp rating for the appropriate voltage (120V, 208/240V). See Section C
for factory setting wiring.
8. Make wall switch and or wall mounted thermostat connections as outlined in Section D.
9. Place all connectors inside the unit and secure the junction box cover to unit. Ensure that the cable clamp grips only the
jacket of service cable, thermostat and if applicable wall switch lines.
WARNING: Ensure method of installation does NOT obscure the air intake slots on bottom front of unit in any manner.
(See diagram in Section A)
Rated
Remote
Power
Voltage
Control
(Watts)
120/120/
245/1440/
Optional
208/240
2100/2700
Wall
Refractory
Brick Look
Thermostat
Included
Included
Optional
N/A
Included
N/A
Current Draw (Amps)
No Heat
120V
208V
120V
2.0
12.0
10.10
2.0
12.0
10.10
2.0
12.0
10.10
2.0
12.0
10.10
2.0
12.0
10.10
240V
11.25
11.25
11.25
11.25
11.25
3