Advertisement

Figure 17. Completed log set assembly.
4. Place the front log on the single log pin so that the
left end of the log rests on the log support and the
andiron holder- directly above the air shutter.
5. Place the cross-over log on the two remaining pins-
top right to the rear log, bottom left on the front log.
See fig. 17.
6. Install the embers: the insert is shipped with a
package of ember stones. Spread them evenly across
the burner tube screen. It is best to equally space
these embers for optimum flame appearance. NOTE:
YOU DO NOT NEED TO USE ALL OF THE EMBER
STONES.
7. Replace the andiron set, center in the firebox over the
andiron support.
THE CERAMIC FIBER LOGS AND EMBER STONES CAN
IRRITATE YOUR SKIN. IF THIS HAPPENS, GENTLY WASH
HANDS WITH WARM, SOAPY WATER.
16

Blower Operation

The GI 450 DV Katahdin is equipped with a 125 cfm
heat-activated blower. A ten foot power cord is in-
stalled in the rear of the valve compartment under the
firebox.
Open the Lower Grill and fully unwrap the power
cord. The cord can exit either the right or left side of the
insert. Be sure to pull all slack out of the power cord to
prevent contact with the bottom of the firebox.
The is equipped with a three-prong (grounding)
plug for protection against shock hazard and should be
plugged directly into a properly grounded three-prong
receptacle. DO NOT CUT OR REMOVE THE GROUNDING
PRONG FROM THE PLUG.
The blower must be electrically grounded in
accordance with local codes or, in the absence of local
codes, with the current NFPA 70- National Electrical
Code or CSA C22.1-Canadian Code.
The blower is controlled by a heat activated switch
(snapstat) that will function only if the blower control
switch is in the AUTO setting. Once the firebox heats
after the burner has been operating for a short time,
the blower will start on either the HI or LOW speed. In
AUTO mode, the blower will continue to operate after
the burner is turned off, until the snapstat cools. See fig. 18.
If blower operation is not desired, place the control
switch in the OFF position to bypass the snapstat
function.
ALWAYS UNPLUG THE BLOWER WHEN
SERVICING THE APPLIANCE.
SPEED
HI
OFF
LO
BLOWER
Figure 18. Blower Controls
NOTE:
MODE
MAN
OFF
AUTO