FREESTANDING OPTIONAL EQUIPMENT (Continued)
5. Blower, Rear (Continued)
REAR BLOWER OPERATION
The blower controls are located on the switch box
that is connected by a cord to the blower. There
are two rocker switches that determine the speed
and mode (automatic or manual) of the blower.
The two speeds are RUN (slower) and STARTUP
(faster). The two modes are AUTO (the
thermodisk controls the switch and the
temperature of the firebox will determine when the
blower starts or stops) and MAN (manual Ð the
blower will run on the speed setting selected).
The blower should be switched "OFF" for
approximately 30 minutes after each reload of the
stove. This is to allow the stove to reach
operating temperature.
RUN
OFF
STARTUP
AUTO
OFF
MAN
Page 11
Speed Control Rocker Switch
(If OFF is selected, the blower
will always be off, even if on
automatic)
Mode Rocker Switch (If OFF
is selected, the blower will
always be off, no matter what
the speed setting is at)