XCP Issues Fixed in Releases Earlier Than XCP
TABLE 6
ID
Description
RTIF1-
Power failure at the commercial AC supply
081016-001
connector to the UPS does not send
notification/send trap.
RTIF1-
In Internet Explorer 6 or 7, clicking on the
081016-003
[Reset] button then the [OK] button from the
Settings->Audit->Add Policy poupup screen
will log the user out with message:
Error
Session Error
Session ID has been expired 
RTIF1-
When the timezone other than three characters
081030-002
has been set, the error logs cannot be
displayed on XSCF Web "Error Log" page.
In addition, XSCF Web "Panic Log" and "IPL
Message Log" pages display the date on the
table with "---".
RTIF1-
The monitor message log might not be
081104-001
registered when a PCI slot error detected.
RTIF1-
The domain console may display this message:
090108-001
ipsec_check_inbound_policy: Policy
Failure for the incoming packet
(not secure)
RTIF1-
In the dual power feed system, when the
090108-002
power failure and the power recovery
occurred repeatedly on one line, all domains
will be forcibly powered off. And in the power
recovery from the forced power-off, a PSU
illegal configuration might be registered in the
error log and the power recovery might not be
started.
RTIF1-
When you execute the settelnet -c
090115-001
disable command, the Telnet service will be
stopped immediately. However, unless you
reset XSCF by using the rebootxscf(8)
command, you might fail in the subsequent
restart of the Telnet service.
RTIF1-
"Power recovery" message is output before
090122-001
a PSU has recovered.
1091
(Continued)
Workaround
No workaround is available.
Log back into the browser interface and use
the backspace key to clear text in the 'User'
text box of the popup screen instead of using
the Reset button.
Use the showlogs(8) command on the XSCF
shell.
No workaround is available.
Use the showlogs error command or the
fmdump command to check the fault
information of PCI slot.
This message can be safely ignored.
You need to remove and insert the power
cable.
After you stopped the Telnet service, execute
the rebootxscf(8) command to reset XSCF.
After the "Power recovery" message is
output, wait 60 seconds before removing
power from another PSU.