PROBLEM
Auger runs in Counterclockwise
(CCW) direction.
Unit does not shut off with cover off
of Waste Xpress unit.
Hot Water Spray is cold.
Hot Water spray does not work.
Auger reverses direction on
each re-start.
Waste Xpress unit will not start.
Water Shuts off when unit shuts off.
If the Waste Xpress remains inoperative after following this troubleshooting guide, contact InSinkErator's service department at
1-800-845-8345 for the location of the nearest approved service agency.
Troubleshooting
WASTE XPRESS TROUBLESHOOTING
POSSIBLE CAUSE
•
Power to auger motor reversed.
•
Waste Xpress Interlock not
operating properly.
•
Incorrectly plumbed.
•
No hot water.
•
Incorrectly wired.
•
Waste Xpress unit auger motor
has been wired into disposer
motor circuit.
•
Incorrect wiring.
•
Misaligned Interlock switch on chute.
•
Improper dipswitch setting
(circuit board).
•
Reverse motor leads to auger motor or
switch L1 and L2 connections on WX
terminal block. Auger must run in
Clockwise direction.
•
Check interlock switch #3 and #95
connections on WX-101A to WX.
•
Call service
•
Connect solenoid on WX unit to hot
water source.
•
Ensure hot water heater/source
is functioning.
•
Check connections on WX-101A #7 to
WX #18.
•
Re-wire as shown in instructions.
•
Check wiring.
•
Check chute for tight fi t.
•
Refer to Page 14 to refer to dipswitch
setting instructions.
21
SOLUTION