Rep 10.1 Fuser Assembly; Rep 10.2 Main Fuser Assembly - Xerox Phaser 790 Service Manual

Hide thumbs Also See for Phaser 790:
Table of Contents

Advertisement

REP 10.1 Fuser Assembly

Parts List on PL 8.1
Removal
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Exit Tray Assembly (REP 8.30).
3.
Remove the Fuser Assembly (Figure 1).
Replacement
1.
Reinstall the Fuser Assembly in the reverse order of removal.
4
Pull out and lift
diagonally to
remove the Fuser
Assembly
3
Remove the screw
Figure 1 Removing the Fuser Assembly
Initial Issue
Phaser 790/DocuColor 2006
WARNING
1
WITHOUT DUPLEX
TRAY OPTION:
Remove screw and
remove the cover
2
WITH DUPLEX
TRAY OPTION:
Open the Duplex
Tray

REP 10.2 Main Fuser Assembly

Parts List on PL 8.2
Removal
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Main Fuser Assembly (Figure 1).
Replacement
1.
Reinstall the Main Fuser Assembly in the reverse order of removal.
2.
Reset the Main Fuser Assembly counter (refer to Section 6, General Procedures).
3
Remove the rear
screws
2
Disconnect the
connectors
Figure 1 Removing the Main Fuser Assembly
10/00
4-113
WARNING
4
Remove the
front screw
5
Remove the
Main Fuser
Assembly
1
Open the Fuser
Assembly