H. Removing Metal Floor of Factory-Built Firebox
The fi rebrick (refractory), glass doors, screen rails, screen mesh
and log grates can be removed from a factory-built fi rebox in
order to gain minimum insert opening requirements.
Any smoke shelves, shields and baffl es may be removed from
a factory-built fi rebox if attached with mechanical fasteners.
The metal fl oor of the factory-built fi rebox may be removed to
facilitate the installation of the insert only when a 1/4 (6mm)
inch airspace is provided between the insert and the fl oor of
outer wrap.
The following is only one example as there are many differ-
ent models of factory-built fi replaces.
Figure 11.1. Measure and mark the metal fl oor for cutting. With a
drill, make a starter hole in each corner.
Figure 11.2. Using a saws-all, cut out the fl oor.
Figure 11.3. Ensure that the power cord can not be damaged by
the sharp metal edge. You may need to cut out a notch to accom-
modate the cord.
NOTE: If the fl oor is made of thin metal, we recommend using the
2 x 4 from the insert packaging to support the insert. The 2 x 4
may need to be cut to the appropriate size. Ensure that the level-
ing leg is positioned over the 2 x 4 before leveling the insert.
November 14, 2011
I. Altering the Factory-Built Fireplace
• The fi replace must not be altered, except for the
exceptions listed below. Do not removal the bricks
and mortar from the existing fi replace.
The following modifi cations are premissible:
• Removal of damper or locked in open position
• Removal of smoke shelf or baffl e
• Removal of ember catches
• Removel of fi re grate
• Removal of view screen/curtain
• Removal of doors
• External trim pieces which do not affect the operation
of the fi replace may be removed providing they can
be stored on or within the fi replace for reassembly if
the insert is removed.
• The permanent metal warning label provided must be
attached to the back of the fi replace, with screws or
nails, stating that the fi replace may have been altered
to accommodate the insert, and must be returned to
original condition for use as a conventional fi replace.
Figure 12.4.
• If the hearth extension is lower than the fi replace
opening, the portion of the insert extending onto the
hearth must be supported.
• Manufacturer designed adjustable support kit can be
ordered from your dealer.
• Final approval of this installation type is contingent
upon the authority having jurisdiction.
NOTE: Refer to chimney liner manufacturer for
recommendations on supporting the liner. Instal-
lation into fi replaces without a permit will void the
listing
THIS FIREPLACE MAY HAVE BEEN ALTERED
TO ACCOMMODATE AN INSERT. IT MUST BE
RETURNED TO ITS ORIGINAL CONDITION
BEFORE USE AS A SOLID FUEL BURNING

FIREPLACE.

Figure 11.4
7019-221C
Santa Fe Pellet Insert
WARNING
250-2061
250-2061