Product Features; High Elevations; Gas Pressures; Gas Specifications & Orifices - Monessen Hearth BDV300N/PV7 Installation And Operation Instructions Manual

Bdv7 series direct vent gas fireplace
Table of Contents

Advertisement

PRoDuCt FeAtuReS and GAS SPeCIFICAtIoNS
PRoDuCt SPeCIFICAtIoNS
This appliance has been certified for use with either
natural or propane gas. Refer to appropriate data
plates.
This appliance is not for use with solid fuels.
The appliance is approved for bedroom or bedsitting
room installations.
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
This appliance is mobile home approved.
The appliance must be properly connected to a venting
system.
The appliance is not approved for closet or recessed
installations.
Hi/Lo Knob
Off/Pilot/On Knob
On/Off/RS Switch
Ignitor
Blower Control
Figure 1 -
BDV300/400/500/600 Fireplace
(Millivolt Control Shown)

hIGh eleVAtIoNS

Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
FP2087
For elevations above 4,500 feet (1,370 m) in USA,
installation must be in accordance with the current
DVB features
ANSI Z223.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installation at eleva-
tions above 4,500 feet (1,370 m).

GAS PReSSuReS

Inlet Minimum
Inlet Maximum
Manifold Pressure
20301836
FP2087
Optional Remote
Receiver
Natural
Propane (LP)
4.5" w.c.
11.0" w.c.
10.5" w.c.
13.0" w.c.
3.5" w.c.
10.0" w.c.
BDV7 Series Direct Vent Gas Fireplace
GAS SPeCIFICAtIoNS & oRIFICe SIZe
Model
Fuel
BDV300NV7
Nat.
BDV300PV7
LP
BDV300NSC7
Nat.
BDV300NPC7
LP
BDV400NV7
Nat.
BDV400PV7
LP
BDV400NSC7
Nat.
BDV400NPC7
LP
BDV500NV7
Nat.
BDV500PV7
LP
BDV500NSC7
Nat.
BDV500PSC7
LP
BDV600NV7
Nat.
BDV600PV7
LP
BDV600NSC7
Nat.
BDV600PSC7
LP

BeFoRe you StARt

Read this homeowner manual thoroughly and follow all
instructions carefully. Inspect all contents for shipping
damage and immediately inform your dealer if any damage
is found. Do not install any unit with damaged, incomplete,
or substitute parts. Check your packing list to verify that
all listed parts have been received. You should have the
following:
Fireplace (Firebox and Burner System)
Rock Wool
Log Set
IteMS RequIReD FoR INStAllAtIoN
Phillips Screwdriver
Hammer
Saw and/or saber saw
Electric Drill and Bits
Pliers
Square
Caulking Material (Noncombustible)
Fireplace Surround Material (Noncombustible)
Piping Complying with Local Codes
Pipe Sealant Approved for use with Propane/LPG
(Resistant to Sulfur Compounds)
Max.Input
Min. Input
BTU/h
BTU/h
21,000
15,000
21,000
15,000
21,000
15,000
21,000
15,000
24,000
17,000
24,000
17,000
24,000
17,000
24,000
17,000
26,000
20,000
26,000
20,000
1.55 mm
26,000
20,000
26,000
20,000
1.55 mm
26,000
20,000
26,000
20,000
1.55 mm
26,000
20,000
26,000
20,000
1.55 mm
Framing Materials
Wall Finishing Materials
Level
Tee Joint
Measuring Tape
Pipe Wrench
Orifice
Size
#43
#54
#43
#54
#41
#53
#41
#53
#40
#40
#40
#40
5