Optional Fan/Blower Systems; Blotsc Signature Command System - Monessen Hearth BDV300N/PV7 Installation And Operation Instructions Manual

Bdv7 series direct vent gas fireplace
Table of Contents

Advertisement

oPtIoNAl FAN BloWeR SySteMS
electrical Grounding Instructions: this
appliance is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged directly
into a properly grounded three-prong
receptacle.
the black and white wires on the AC box
wiring harness are marked 'Blower', 'light'
and 'Aux'. It is important to use the wires
marked 'Blower' or the control will not work
correctly.
BlotSC SIGNAtuRe CoMMAND BloWeR
To Junction Box
In Fireplace
Blower (300w Max)
The BLOTSC Blower Kit requires the SCSACM A/C Mod-
ule and the TSFSC remote to install and operate this kit.
Refer to blower instructions for installation.
20301836
Optional
{
Light
WHITE
BLACK
WHITE
BLACK
BLACK
{
Optional
WHITE
AUX
Figure 54 -
Blower Wiring Diagram
FP2103
AC fan wiring
electrical connections should only be
performed by a qualified licensed electrician.
Main power supply must be turned off before
connecting the fan to the main electrical
power supply or performing service.
GREEN
Connector
Pin To Contro  l  Box
Control Box
BDV7 Series Direct Vent Gas Fireplace
optional AC
Module
FP2103