sIGnature cOMManD - OptIOnal Fan BlOWer systeM
a/c WIrInG tO junctIOn BOx
IMpOrtant: always check local building codes.
this installation must comply with local regulations
as well as the national electric code.
WIrInG
1. Before installing the blower, wire the receptacle into an
electrical circuit. This should be done before framing the
fireplace. Wire with minimum 60° C wire in accordance
with prevailing codes.
2. Remove the external junction box cover by removing
the screw from the right side of the outside firebox wall.
Junction box was installed at the factory.
3. The junction box cover has a factory installed "romex"
style strain relief connector. After connecting the wires,
route the wire leads through this connector. Refer to the
wiring diagram in Figure 33.
OptIOnal Fan/BlOWer systeM (BlOtBlDVsc)
Blower
Right
Blower
Left
Figure 34 -
Blower Wiring Diagram
Electrical Grounding Instructions: This appli-
ance is equipped with a three-prong (grounding)
plug for your protection against shock hazard
and should be plugged directly into a properly
grounded three prong receptacle.
78D0011
To Junction Box
In Fireplace
{
Light
White
Black
White
Black
Black
{
White
AUX
FP1915
AC box wiring
8/08
junction Box
Figure 33 -
Junction Box Wiring Diagram
Before installing the blower, turn off the fireplace and
FP1912
allow to cool. Only a qualified service person should
Junction box wiring
service and repair the fireplace. A qualified service
person should connect and disconnect the fireplace
8/08
to gas supply. Follow all local codes.
AC Module
Green
Connector
Pin To Control Box
Control Box
WDV Series Gas Fireplace
120V AC
60Hz
Factory Supplied
Not Supplied
FP1915