Installation
Using the provided template, mark the locations of the 6
fixing screws on the wall, taking care to ensure the base of
the appliance will be at least 650mm above your hob when
installed. Fit the wall plugs as shown and then fix two screws
in the holes shown, leaving about 5mm protruding as shown
in figure 9.
When installing this appliance over a CDA hob, the clearance
between the extractor and the hob must be equal to or
exceed 650mm. This instruction overrides the instructions
supplied with the CDA hob. (The height should be measured
from the top of the hotplates or burners)
Where the extractor is to be installed above a non-CDA hob,
the instructions supplied with the hob may dictate that the
height required above the hob is greater than 650mm.
IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED
WITH THE HOB, THE MINIMUM DISTANCE BETWEEN
THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm
Hang the motor body assembly on the 2 screws and tighten;
make any small positional adjustments and then fix the 2
lower screws to secure the motor assembly to the wall.
a. If using the extractor as a recirculation device or
extracting through a rear wall, fit the vent cover to the
wall using the remaining screws and secure in position.
Fig 11
b. If using the extractor to extract out through the ceiling,
pry of the vent cover as in fig, fit and secure it to the wall
using the remaining screws and then assemble the vent
pipe as shown in fig 12
7
Fig. 9
Fig. 10
Fig. 11
Fig. 12