Advertisement

EVX90SS
Ceiling extractor
Use and maintenance

Advertisement

Table of Contents
loading

Summary of Contents for CDA EVX90SS

  • Page 1 EVX90SS Ceiling extractor Use and maintenance...
  • Page 2: Table Of Contents

    Contents Important information Using your extractor Care and maintenance Installation instructions for standard fitting Installation instructions for mounting the motor externally Ducting Recirculation Mains electrical connection Guarantee Troubleshooting 20 Energy efficiency information 2 | Instruction Manual...
  • Page 3: Important Information

    Appliance Information: Please enter the details on the appliance rating plate below for reference, to assist CDA Customer Care in the event of a fault with your appliance and to register your appliance for guarantee purposes. Appliance model...
  • Page 4 IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2012/19/EU. At the end of its working life, the product must be taken to a special local authority waste collection centre or to a dealer providing appliance recycling services. Disposing of a household appliance separately avoids possible negative consequences for the environment and health.
  • Page 5: Using Your Extractor

    Using your extractor Controls Power button Light button Low speed button High speed button Timer button Middle speed button Fig. 1 Power button Pressing once will start the extractor at the lowest speed setting, pressing again will turn the extractor off Light button Turn the lights of the extractor on or off High speed button...
  • Page 6: Care And Maintenance

    Care and Maintenance Cleaning You should use a non-abrasive cleaner. Any abrasive cleaner (including Cif) will scratch the surface and leave marks on the extractor. You can clean your extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth.
  • Page 7: Installation Instructions For Standard Fitting

    Installation instructions for standard fitting Please note: All installation measurements given are in millimeters Make a cutout in the ceiling with the measurements below Fig. 2 Dimensions for installation reference 153.5 137.5 137.5 153.5 Fig. 3 Instruction Manual | 7...
  • Page 8 Fix the upper bracket to the support structure Fig. 4 Fasten the lower bracket to the upper bracket with the 8 screws supplied. We recommend having an 85 - 100mm gap between the opening in the ceiling and the lowest point of the lower bracket Fig.
  • Page 9 Locate the extractor in the ceiling opening, make sure to connect your ducting and mains electrical connection before proceeding to the next step Fig. 7 Fix the extractor to the bracket with the 6 screws and washers provided. Tighten evenly on both sides until secure, be careful to not overtighten Fig.
  • Page 10: Installation Instructions For Mounting The Motor Externally

    Installation instructions for mounting the motor externally Remove the 8 screws fixing the motor housing on the extractor and detach it from the casing Fig. 9 Remove the four screws that fix the airguide to the housing and remove it Fig.
  • Page 11 Connect the two duct adaptors on both of the panels Fig. 11 Fix the airguide to the panel using the four screws removed in Fig. 10; note that the air guide is fixed to the opposite side of the duct adaptor Fig.
  • Page 12 Fix the panel with the airguide to the motor housing with the 8 screws supplied; note that the airguide is facing the motor Fig. 13 Secure the second panel to the rear of the extractor with the 8 screws supplied Fig.
  • Page 13 Secure the motor housing to the support structure using appropriate fixings Fig. 16 Suggested mounting example Fig. 17 Instruction Manual | 13...
  • Page 14 Fix the duct adaptor to the motor housing using the 4 screws provided Fig. 18 Connect the motor and extractor body using a 150mm diameter ducting hose Fig. 19 14 | Instruction Manual...
  • Page 15: Ducting

    Ducting The extractor can be used as a recirculation device or as an extraction device, depending on your installation. The hood is more effective when used in extraction mode (ducted to the outside). When the extractor is ducted to the outside, char- coal filters are not required.
  • Page 16: Recirculation

    Recirculation An internal air vent is required, as shown below. This ensures that the air is placed back in the kitchen after it has been filtered. The internal air vent must be a minimum of 2 metres away from the extractor Min.
  • Page 17: Mains Electrical Connection

    Mains electrical connection Warning! This appliance must be earthed. This appliance must be connected by a competent person, using fixed wiring via a double pole switched fused spur outlet, protected by a 3A fuse. DOUBLE POLE SWITCHED FUSED SPUR OUTLET We recommend that the appliance is connected by a qualified electrician, who is a member of the...
  • Page 18: Guarantee

    • Use of parts not used or • Installation has recommended by CDA been carried out • Routine maintenance, in accordance with general wear, tear and instructions and current installation faults legislations •...
  • Page 19: Troubleshooting

    Troubleshooting In the event of your appliance requiring technical assistance and/or spare parts, please contact CDA Customer Care. In this case it is necessary to state all the appliance data on the rating plate, such as model, serial number etc. This information can...
  • Page 20: Energy Efficiency Information

    Energy Efficiency Information Attribute Symbol Value Units Model Identification EVX90SS Annual Energy Consumption AEC Hood 68.8 Time increase factor Fluid Dynamic Efficiency FDE Hood 27.1 Energy Efficiency Index EEI Hood 62.6 Measured airflow at Best Efficiency Point Q BEP 378.8 m³/h...
  • Page 21 Notes Instruction Manual | 21...
  • Page 22 Notes 22 | Instruction Manual...
  • Page 23 Notes Instruction Manual | 23...
  • Page 24 The CDA Group Harby Road Langar Nottinghamshire NG13 9HY Sales Department Phone: 01949 862010 Email: sales@cda.eu CDA Customer Care Phone: 01949 862012 Email: customer.care@cda.eu ©2020 CDA Group Ltd...