F. Vent Diagrams
1. Top Vent - Horizontal Termination
One Elbow
Note: Use SLP Series
components only.
Fire Risk.
• When using SLP-HRC-SS and SLP-HRC-ZC-SS
termination caps on top vented fi replaces, a one
foot minimum vertical vent section is required
before installing fi rst elbow.
• When using DVP-TB1 termination cap on top
vented fi replaces, a three foot minimum vertical
vent section is required before installing first
elbow.
Figure 7.4
WARNING**
Note: There MUST be a 25% reduction
in total H when using fl ex vent except
when using the simple up and out
installation (see Figure 7.3).
Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10
V
Minimum**
1
90 Elbow Only**
1/2 ft.**
152 mm
1-1/2 ft.** 457 mm
2-1/2 ft.** 762 mm
3-1/2 ft.
1.1 m
4-1/2 ft.
1.4 m
H
MAX. =15 ft. (4.6 m)
1
V
+ H
MAX. = 40 ft. (12.2 m)
1
1
** See Warning.
H
1
H
Maximum
1
2 ft.
610 mm
2 ft.
610 mm
3 ft.
914 mm
5 ft.
1.5 m
7 ft.
2.1 m
15 ft.
4.6 m
V
1
25