To remove the thermistor:
1. Disconnect power to the machine.
2. Remove the back cover. (See
3. Remove the wire ties from the thermistor.
4. Disconnect the wiring connector at the
thermistor.
5. Remove the 2 Phillips-head screws that hold the
thermistor to the bottom of the outer tub.
6. Pull the thermistor straight out from the outer
tub.
Caution: To prevent water leakage, make sure the
O-ring is in place before installing the thermistor.
, step 1.)
Top Cover
Wire Ties
Disconnect
O-ring
– 31 –
Heater
•
The heating element is used only on the
SANITIZE cycle.
•
The power board regulates the heating
element through information received from the
thermistor/ATC control.
•
The heating element is located above the drain
at the bottom of the outer tub.
•
The heating element is inserted into a bracket
attached to the high limit thermostat and held in
place by a 10-mm hex nut.
•
When the 10-mm hex nut is tightened, it
squeezes the rubber gasket between the 2
mounting plates to seal the heater to the
opening of the tub.
•
The hex nut is set from the factory at 43.4 in. lbs
(4.9 Nm) of torque.
Heating Element Specifi cations:
•
120 VAC
•
1200 Watts
•
9.0 Amps
•
12.5 Ω
To remove the heater:
Note: The heating element must be removed before
removing the hi-limit thermostat.
1. Disconnect 2 wires from the terminal ends of the
heating element.
2. Remove the three 8-mm hex-head screws
holding the heating element bracket in place .
Remove the bracket.
Disconnect