Flames regulation of the oven burner
Because of different gas mixtures in the distribution system, you may have flames with
too much or too little air. In such cases, loosen the screw and move the air ring to
close or open the air flow, until the regular flame is obtained (fig. 7).
Standard position of the air ring.
Natural Gas: Positioning the indicator line of the air ring to the symbol N printed on
the burner.
L.P .G.: Fully open the air ring.
Warning: The regulation of the flames must only be carried out by a Corgi registered
fitter.
Opening ring.[mm]
G
Figure 6
Figure 7