Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
55
(Small)(A)
Triple Crown
130
(TC)
Supply
Pressures
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
S
S
R
A
K 645 V.C/G
K 645R V.C/G
Burner and nozzle characteristics
Thermal Power
kW (p.c.s.*)
Nominal
Reduced
3.00
0.7
1.90
0.4
1.00
0.4
3.25
1.5
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
3
S
R
TC
A
K 647R V.C/G
Liquid Gas
By-Pass
Nozzle
1/100
1/100
(mm)
(mm)
***
41
86
218
30
70
138
30
50
73
63
91
236
28-30
20
35
7
Natural Gas
Flow*
Nozzle
g/h
1/100
**
(mm)
214
116
136
106
71
79
232
133
37
20
25
17
45
25
Flow*
l/h
286
181
95
309