6.8 Malfunctioning of cooler air temperature sensor

If during the normal operation a failure occurs to the cooler NTC temperature sensor (the signal coming from
the sensor is out of range), then:
The display shows cooler temperature sensor faulty.
The air flow regulator (damper) operates as follows:
-
open when the compressor is on
-
closed when the compressor is off.
The defrosting procedure is activated every about 10 hours.
When the sensor operates again normally, the above described conditions terminate.
Characteristics of the NTC sensor: