5.3.1 Temperature sensor
1 NTC sensor detects the temperature of the cooler:
•
cooler air temperature sensor (placed inside the right air vent grid)
The cooler air temperature sensor is used both to control the appliance by means of the air flow regulator
(damper) and to display the cooler compartment temperature.
The sensor A has the foamed cable inside the cabinet, therefore it is not replaceable (for further information
please see Service Bulletin 599374122).
5.3.2 Door switch
The battery evaporator defrosting is driven by the electronic board and depends also on the detection of the
opening of the doors.
The detection of the opening of the cooler door is carried out by means of:
•
magnetic switch for the cooler door control (located on the display board inserted into the work top)
The magnetic switch for the cooler door control is activated by a magnet located inside the cooler door.
The magnetic switch controls also the switching on of the lamp and of the LED lighting if featured (optional de-
pending on the models).
- ITZAA
18/44
599 38 47-44