Flow Chart For The Defrosting Management - AEG Electrolux REFRIGERATION Service Manual

No frost total with erf2050 electronic digits aeg styling
Table of Contents

Advertisement

6.4 Flow chart for the defrosting management

More than 5 h elapsed after power on &
compressor off or compressor on for more
than 2,5 h?
yes
DEFROSTING
Resetting door accumulated timer
SUPER function activated?
no
More than 14 h elapsed after the last
defrosting & cooler or freezer door is open
from more than 6 minutes?
no
More than 14 h elapsed after the last
defrosting & comp on for more than 2,5 h?
no
More than 30 h elapsed after the last
defrosting & cooler or freezer door is open
from more than 1 minute?
no
More than 72 h elapsed after the last
defrosting?
no
DEFROSTING
- ITZAA
START
no
yes
yes
yes
yes
yes
29/44
no
More than 14 h elapsed after
the last defrosting?
yes
DEFROSTING
599 38 47-44