Heat & Glo 6000PLUS Owner's Manual page 11

Vented gas fireplace
Table of Contents

Advertisement

For Intermittent Pilot Ignition (IPI) Wiring
3 Volt Transformer
This appliance comes with a 3 volt transformer. The trans-
former plugs into the junction box, and the two leads plug
into the green control module (see Figure 8).
Appliance Requirements
This appliance requires that 110-120 VAC be wired to the
junction box included in the manual bag assembly. Maintain
correct polarity when wiring the junction box.
PLUG-IN
3V TRANSFORMER
ON/OFF
WALL SWITCH
IGNITION
MODULE
(3V)
VALVE
GROUND
NEUTRAL
Figure 8.
Intellifire Wiring Diagram
14
TRANSFORMER
3 VAC
TRANSFORMER
OUTLET
ORANGE
FLAME SPARKER /
SENSOR
TO "H1" ON
HRV200 PLUS BOARD
LOW VOLTAGE
SEE NOTE 1
REMOTE
TO "R2" ON
HOT
CONTROL
HRV200 PLUS
BOARD
Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05
Optional Accessories
Optional fan and remote control kits require that 110-120
VAC be wired to the fireplace junction box.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERA-
TION. VERIFY PROPER OPERATION AFTER SERVICING.
IGNITOR MODULE 3 VAC
PLUG-IN
BROWN
TEMP SENSOR
BLUE
TO "12V" ON
HRV200 PLUS BOARD
TO "R1" ON
HRV200 PLUS
BOARD
INTERMITTENT PILOT IGNITOR
I
S
WHITE
(SENSOR)
ORANGE
(IGNITOR)
GROUND TO
FIREPLACE
CHASSIS
VALVE

Advertisement