2.2 Connection of Optional Sensors

Water temperature sensor
Connect the transducer cable to the XDR connector. Connect the
water temperature sensor (option) or water temperature/speed sen-
sor (option) to the XDR connector with the converter connector
(Type : 02S4147 , Code No. : 000-141-082,option).
MJ-A6SRMD
SHIELD
TEMP
TEMP0V
NC
NC
NC
MJ-A10SRMD
NC
NC
NC
NC
NC
NC
NC
XDR+
XDR SHIELD
XDR-
Figure 2-4 Connection of water temperature speed sensor
Water temperature/speed sensor
MJ-A6SRMD
SHIELD
TEMP
TEMP0V/SPD0V
SPD
+V
NC
MJ-A10SRMD
NC
NC
NC
NC
NC
NC
NC
XDR+
XDR SHIELD
10
XDR-
Figure 2-5 Connection of water temperature/speed sensor
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
MJ-A10SPF
1
NC
4
TEMP
7
TEMP0V
3
NC
2
NC
5
NC
6
NC
8
XDR+
9
XDR SHIELD
10
XDR-
MJ-A10SPF
4
TEMP
7
TEMP0V
3
SPD0V/ SHIELD
1
SPD
2
+12.7V
5
NC
6
NC
8
XDR+
9
XDR SHIELD
10
XDR-