ELECTRICAL & GAS CONNECTION LOCATIONS
models EFE916BA, EFE956BA
Gas connection point to regulator
168
models: EFE916BA
Electrical connection cable
Installing the gas cooker
Gas pressures
The following table shows the supply and operating
pressures for various gases.
Gas type
Supply pressure at inlet
to appliance regulator (if
fitted)
Operating pressure at
appliance test point
The following table shows the injector sizes for
each burner.
Injector Orifice
Low heat burner
medium heat burner
Intense heat
dual wok burner
Electrical cable
entry point
models:
EFE916BA,
EFE956BA
95
natural
Universal
gas
LpG
1.13 (kPa)
2.75
minimum
kPa
1.00 (kPa)
2.60 kPa
natural gas Universal LpG
1.00mm
0.55mm
1.35mm
0.70mm
0.85mm
0.46mm
(inner)
(inner)
2 x 1.25mm
2 x 0.73mm
(outer)
(outer)
Checking piping size
To work out a suitable pipe size for connection use the
information in this table:
model
natural gas
EFE916BA
66.1 mJ/h
Information about the length of run, number of elbows,
tees and bends, the available service pressure and the
supply requirements.
NOTE: AS/NZS5601.1 will help you with this matter.
Gas connection
Read these points before connecting to the gas supply:
• T he appliance is preset for natural gas use. If LPG is
to be used see Conversion to LPG section.
• G as installation must be made in accordance with
AS5601, the local gas fitting regulations, municipal
codes and other statutory regulations.
• T he gas connection point is a ½" BSP external thread
located at the rear of the appliance as shown.
• A regulator is supplied which must be fitted to the
appliance. Ensure that when fitted the pressure test
point of regulator is accessible.
• T he regulator is to be fitted to the appliance
connection point, then fit hard piping from the
regulator to the consumer hard piping. Ensure the
installation allows the withdrawal of the appliance.
• T he appliance as supplied is not approved for
connection with a flexible hose. However, an approved
flexible hose kit ACC064 is available if the installation
requires use of flexible hose.
Universal LpG
57.5 mJ/h

Hide quick links: