IMPORTANT: Leave an air space around each
coal to allow easy flow of products of combustion,
too much impingement of flame on coals will
cause sooting.

LIGHTING

First Lighting-
Purge air from the supply line as follows:
a.
Open main shut-off valve. Unscrew inlet
pressure test point. Leave open inlet test
screw until gas comes.
b.
When gas comes tighten inlet screw
immediately.
WARNING:
Do not purge the system near a
naked flame or hot surface.
Press in the control knob all the way. Turn anti-
clockwise until you hear a clicking sound. Keep
control knob pressed for 15-30 seconds. Release
control knob. If the pilot fails to light repeat this
action.
WARNING: Do not operate the stove with the
appliance door open, or if the glass panel in the
front door has been broken or removed.
Ensure the door latch is fully locked. Keep the
door spin valve closed at all times when the stove
is in operation.
Fig.29
During the first light up period an odour will rise
from the stove, this is due to the materials in the
stove drying and curing. It is advisable to open a
window or door to give extra ventilation to the
room until the odour has gone.

BURNER LIGHTING

1.
2.

SPILLAGE TEST

NOTE: It is essential that every flue system be
inspected and tested by the installer upon com-
pletion, to ensure that the combustion products
are completely discharged to the outside atmos-
phere.
When the stove is installed carry out a spillage
test (See Fig.30) as outlined in the following
procedure:
a.
b.
c.
d.
Fig.30
e.

PILOT FLAME

NOTE: The pilot flame should be a steady blue
flame which has contact with the upper 3/8" of the
thermopile. (See Fig 31)
Fig.31
11
With the pilot flame firmly established turn
the control knob anti-clockwise to the high
position. When the main burner is lighting
adjust control knob clockwise to a lower
setting if required.
If the pilot light is extinguished either inten-
tionally or unintentionally no attempt
should be made to light the gas until at
least 4 mins. have elapsed.
Operate stove for a minimum of 10 mins.
at maximum setting.
Run all other combustion appliances
and/or extraction fan/s fitted in the room or
adjacent rooms at full setting e.g. clothes
dryers, furnaces etc.
Close windows and external doors.
With a smoke match, joss stock or smoke
puffer run around 1" (25mm) from the edge
of the down draught opening. (See Fig.
30).
If all the smoke is pulled into the down
draught opening, there is no spillage.
CORRECT FLAME
INCORRECT FLAME