Oscar Solid Fuel Stove
This appliance is hot while in operation and retains its heat for a long period of time after use.
Children, aged or infirm persons should be supervised at all times and should not be allowed
to touch the hot working surfaces while in use or until the appliance has thoroughly cooled.
When using the stove in situations where children, aged and/or infirm persons are
present a fireguard must be used to prevent accidental contact with the stove. The fireguard
should be manufactured in accordance with BS 6539.
INSTALLATION AND OPERATING INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Stanley Oscar

  • Page 1 Oscar Solid Fuel Stove This appliance is hot while in operation and retains its heat for a long period of time after use. Children, aged or infirm persons should be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PAGE NO. General ............. . Handling .
  • Page 3: General

    OSCAR SOLID FUEL NON-BOILER STOVE INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT WARNING: This stove must not be NOTE: Please note that it is a legal requirement installed into a chimney that serves any other under England & Wales Building Regulations that heating appliance.
  • Page 4: Chimney

    chimney is not available a proprietary type 125 – Fig.1 150mm twin wall, fully insulated pipe may be used. The pipe must terminate at a point not lower than the main ridge of adjacent outside obstructions. With such installation, access to the chimney must be provided for cleaning purposes.
  • Page 5: Down Draughts

    VENTILATION AND COMBUSTION AIR Fig.3 REQUIREMENTS 2300 min min. This appliance is rated at 5kW. There is no addi- tional air requirement unless a flue draught stabilis- min. er is fitted then the air requirement is 15cm . When calculating combustion air requirements for this appliance use the following equation: 550mm each kW of rated output above 5 kW should be pro- vided, where a flue draught stabiliser is used the...
  • Page 6: Permanent Air Vent

    If spillage occurs following the above operation, an CLEARANCE TO COMBUSTIBLES additional air vent of sufficient size to prevent this occurrence should be installed. It is recommended that this appliance is sited next to and on a non-combustible surface. A minimum all PERMANENT AIR VENT round clearance of 100mm will allow air circulation and not impede the performance of the stove.
  • Page 7: Recommended Fuels

    for a minimum heat output and burn rate rotate the RE-FUELLING spin valve clockwise until fully closed. For nominal heat output the spin wheel will need to be open Riddle the fire by connecting the grate operating tool between 1 and 2 turns depending upon the draught onto the rocker connection located at the bottom of the chimney.
  • Page 8: Important Notes

    IMPORTANT NOTES Now that your Stanley Solid Fuel stove is installed and no doubt you are looking forward to many comforts it will provide, we would like to give you some tips on how to get the best results from your stove.
  • Page 9: Lighting

    Before lighting the stove check with the installer that the installation work and commissioning checks described in the installation instructions have been carried out correctly and that the chimney has been swept clean, is sound and free from any obstructions. As part of the stoves commission- ing and handover the installer should demonstrate how to operate the stove correctly.
  • Page 10: De-Ashing

    DE-ASHING WARNING NOTE Never allow the ashpan to over fill as it will cause damage to the grate. Open the fire door (Part Properly installed, operated and maintained this No.21) and remove ashpan (Part No.12) using the stove will not emit fumes into the dwelling. operating tool (Part No.34).
  • Page 11: Glass - Cleaning & Replacement

    RHS side brick forwards and down, CO ALARM then lift out. Waterford Stanley recommend the fitting of a CO 7. Move the back brick fully to the RHS, pull the Alarm in the same room as the appliance, this is a back LHS side brick fully forward until it meets the requirement under UK Building Regulations.
  • Page 12: Exploded View

    OSCAR SOLID FUEL STOVE EXPLODED VIEW Legs 12. Ashpan 22. Spin Valve Base 13. Side Bricks 23. Grate Shaker Control Knob Base Sealing Tape 14. Back Brick 24. Door Handle Front 15. Top Baffle 25. Door Hinges Left Hand Side 15a.Top Protection Baffles...