Air Controls; Lighting; User Instructions - Stanley Oisin Eco Installation And Operating Instructions Manual

Solid fuel stove
Table of Contents

Advertisement

AIR CONTROLS

Primary air control
The spin valve, located in the door, controls the pri-
mary air supply to the stove. For maximum heat out-
put and burn rate on smokeless coal rotate the spin
valve fully in an anti-clockwise direction and for a
minimum heat output and burn rate rotate the spin
valve clockwise until fully closed. (See Fig.6)
Note:
The controls may become hot when the stove is in operation, use tool or glove provided to adjust the controls
when the stove is hot.
Fig.6
Fuel
Mineral smokeless fuel
(Maxibrite)
Wood

LIGHTING

Before lighting the stove check with the installer that the installation work and commissioning checks
described previously have been carried out correctly and that the chimney has been swept clean, is sound
and free from any obstructions. As part of the stoves commissioning and handover the installer should
demonstrate how to operate the stove correctly.

USER INSTRUCTIONS

1.
Before lighting the stove, ensure that any build-up in the firebox has been removed and that the ashpan
has been emptied.
2.
Open the air controls.
3.
Lay a few crumpled sheets of paper on the hearth and then a few small sticks, kindling or an approved
firelighter.
4.
Ignite and close the door.
5.
Never use inflammable liquid i.e. gasoline, petrol paraffin etc. to start or "freshen up" a fire in
this heater.
6.
When the fire is well established , fuel the stove and adjust the air controls to the required setting.
7.
The appliance must not be operated with the door left open except as directed in the instructions,
operation with teh door left open can cause excessive smoke
8.
Operation with the air controls fully open can cause excessive smoke, the appliance conrtols must be
shut down in accordance with teh table above after the ignition period to prevent excessive smoke.
AIR CONTROLS
Ignition
Primary
Secondary
Fully Open
Fully Open
Fully Open
Fully Open
Secondary air control
The secondary air control is located over the door,
this controls the secondary air / window wash air-
supply to the stove. For maximum heat output and
burn rate on wood pull the control knob out fully, for
a minimum heat output and burn rate push the knob
in fully to close off the air supply. (See Fig.7)
Fig.7
Secondary air
control knob.
Primary
0-80% Open
0-10% Open
13
Controlled Burn
Secondary
Fully Closed
0-80% Open

Advertisement

Table of Contents
loading

This manual is also suitable for:

Oisin nb sf