Dimplex DWF120330B Owner's Manual
Dimplex DWF120330B Owner's Manual

Dimplex DWF120330B Owner's Manual

Dimplex dwf120330b electric fireplace owner's manual
Hide thumbs Also See for DWF120330B:

Advertisement

IMPORTANT SAFETY INFORMATION: Always read this manual first
before attempting to install or use this fireplace. For your safety, always
comply with all warnings and safety instructions contained in this manual
to prevent personal injury or property damage.
To view the full line of Dimplex products, please visit
www.dimplex.com
Owner's Manual
Model
DWF120330B
7213550100R03

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex DWF120330B

  • Page 1 For your safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage. To view the full line of Dimplex products, please visit www.dimplex.com 7213550100R03...
  • Page 2: Table Of Contents

    CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment. WARNING: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
  • Page 3: Welcome & Congratulations

    Welcome & Congratulations Thank you and congratulations for choosing to purchase an electric fireplace from Dimplex, the world leader in electric fireplaces. Please carefully read and save these instructions. CAUTION: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock, fire hazard and will void the warranty.
  • Page 4: Important Instructions

    Dimplex ① Read all instructions before Technical Service at using the electric fireplace. 1-888-346-7539.
  • Page 5: Save These Instructions

    IMPORTANT INSTRUCTIONS overheat and cause a risk of fire. ⑮ Do not insert or allow foreign This heater is not intended for use objects to enter any ventilation with an extension cord. Plug the or exhaust opening as this may cord directly into an appropriate cause an electric shock or fire, or wall receptacle.
  • Page 6 · Consult the dealer or an experienced radio/TV technician for help. Operation is subject to the following two conditions: (1) this device may not cause interference and (2) this device must accept any interference, including interference that may cause undesired operation of the device. www.dimplex.com...
  • Page 7: Quick Reference Guide

    Quick Reference Guide 1. Before using the fireplace 3. The heater may emit a slight, verify the circuit breakers for harmless odor when first the unit on? used. This odor is a normal condition caused by the initial 2. If you have any technical heating of internal heater questions or concerns parts.
  • Page 8: Fireplace Installation

    WARNING: The supplied Volt circuit is required. A mounting bracket is designed dedicated circuit is preferred for use with Dimplex wall but not essential in all cases. mounted fireplaces only. A dedicated circuit will be Improper use, or use for...
  • Page 9 Fireplace Installation Access to the electrical outlet Figure 2 must be maintained. Ensure the installation meets the national and state/provincial 610 mm (24") electrical codes. MINIMUM NOTE: It is recommended that the bottom of the unit not be mounted higher than 1020mm (40") from the Fireplace Installation ground to maintain an optimized...
  • Page 10 (Figure Wall anchor 12. Carefully pour and evenly distribute the supplied glass rock media in the Media tray Screw of the firebox (Figure 6). 13. Hang the front glass as- Wall sembly on the mounts of the bracket www.dimplex.com...
  • Page 11 Fireplace Installation firebox and secure the glass Figure 7 onto the unit by installing the retaining screws (Figure 7) 14. Excess electrical cord can be inserted back into the bottom of the unit, into the cord storage area. Glass Retaining Figure 6 Screw Front Glass...
  • Page 12: Operation

    On Screen ! NOTE: When any button is Display, for 5 seconds before pressed the intake tempera- turning off. ture will be displayed on the On ! NOTE: The unit can be oper- Screen Display for 5 seconds. www.dimplex.com...
  • Page 13 Operation Disable Heat ated in Heat Only Mode. When the unit is only running with the If desired, depending on the sea- heater, the icon and the intake son, the heater on the unit can be temperature will continuously disabled. The unit will operate in be displayed on the On Screen the same fashion, with remainder Display.
  • Page 14 Battery must be recycled CAUTION: If you need to con- or disposed of properly. tinuously reset the heater, unplug Check with your Local the unit and call technical support Authority or Retailer for recycling at 1-888-346-7539. advice in your area. www.dimplex.com...
  • Page 15: Maintenance

    Maintenance Fireplace Surface WARNING: Disconnect Cleaning power before attempting any maintenance or cleaning to Use only a damp cloth to clean reduce the risk of fire, electric painted surfaces of the fireplace. shock or damage to persons. Do not use abrasive cleaners. Partially Reflective Glass Servicing Cleaning...
  • Page 16: Warranty

    Limited warranty service requires a the entire cost of all necessary servicing proof of purchase of the product. or repair. What Dimplex will do in the event of a What this limited warranty covers and for defect? how long...
  • Page 17 DAMAGES ARE FORESEEABLE. IN product or part without charge. If NO EVENT WILL DIMPLEX, OR ITS Dimplex is unable to repair or replace OFFICERS, DIRECTORS, OR AGENTS such product or part, or if repair or BE LIABLE FOR ANY DIRECT LOSSES,...
  • Page 18: Replacement Parts

    Thermistor .........3001380100RP Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 © 2014 Dimplex North America Limited www.dimplex.com...

Table of Contents