Advertisement

IMPORTANT SAFETY INFORMATION: Always read this manual first
before attempting to install or use this fireplace. For your safety, always
comply with all warnings and safety instructions contained in this manual
to prevent personal injury or property damage.
To view the full line of Dimplex products, please visit
www.dimplex.com
Owner's Manual
Model
DWF36
7211490100R02

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex DWF36

  • Page 1 For your safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage. To view the full line of Dimplex products, please visit www.dimplex.com 7211490100R02...
  • Page 2: Table Of Contents

    CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment. W ARNINg: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
  • Page 3: Welcome & Congratulations

    Welcome & Congratulations Thank you and congratulations for choosing to purchase an electric fireplace from Dimplex, the world leader in electric fireplaces. Please carefully read and save these instructions. CAUTION: read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock, fire hazard and will void the warranty.
  • Page 4: Important Instructions

    Do not or repair. use in areas where gasoline, paint, or ⑥ flammable liquids are used or stored Do not use outdoors or where the unit will be exposed to flammable vapors www.dimplex.com...
  • Page 5: Save These Instructions

    IMPORTANT INSTRUCTIONS ⑬ ⑰ Do not modify the fireplace. use it Always use a certified electrician only as described in this manual. Any should new circuits or outlets be other use not recommended by the required manufacturer may cause fire, electric ⑱...
  • Page 6 Consult the dealer or an experienced radio/Tv technician for help. operation is subject to the following two conditions: (1) this device may not cause interference and (2) this device must accept any interference, including interference that may cause undesired operation of the device. www.dimplex.com...
  • Page 7: Fireplace Installation

    Quick Reference guide ③ ① If you have any technical The electrical information questions or concerns regarding regarding your electric fireplace the operation of your electric can be found on the rating label fireplace, or require service located on the bottom of the unit, contact customer service.
  • Page 8 WARNINg: The supplied mounting bracket is designed for use with Dimplex wall mounted fireplaces only. 46" - 62" Improper use, or use for (117 cm - 158 cm) purposes other than intended, may cause damage or injury.
  • Page 9 Fireplace Installation select an appropriate location Figure 3 to mount the unit on a wall, Wall anchor above an electrical outlet. The bottom of the unit must be a minimum of 24 inches (61 cm) above the floor screw (mounting bracket 46 inches Wall (117 cm) above the floor).
  • Page 10 Mount the unit on the wall as media is level in the firebox. shown (Figure 7). (Figure 6) www.dimplex.com...
  • Page 11: Operation

    Fireplace Installation Figure 7 Figure 6 Foam End Wall Bracket Supports Wall Bracket Bare End Operation When the switch is in the “ I ” Figure 8 position, the unit is on. When in the “ O ” position, the fireplace is off.
  • Page 12: Remote Control

    CAUTION: If you need to operation with the remote, pull continuously reset the heater, the plastic insulator strip out from unplug the unit and call between the remote casing and Dimplex customer service at battery cover (Figure 9). 1-888-DImPLEX (1-888-346-7539). www.dimplex.com...
  • Page 13 Operation Remote Control Initialization/ remote control transmitter and the Reprogramming fireplace can be turned off at any point by pressing the oFF button. If the hand held transmitter or receiver board has been replaced, Battery Replacement follow these steps to initialize the To replace the battery: transmitter and receiver: slide battery cover open on...
  • Page 14: Maintenance

    To remove fingerprints or other marks, the mirror can be cleaned with a damp cloth. The mirror should be completely dried with a lint free cloth to prevent water spots. To prevent scratching, do not use abrasive cleaners. www.dimplex.com...
  • Page 15: Warranty

    Warranty Products to which this limited warranty to the provisions of this warranty, Dimplex applies warrants such products to be free from defects in material and workmanship for a This limited warranty applies to the period of 1 year from the date of the first following models of your newly purchased purchase of such products.
  • Page 16 DIrECTors, oFFICErs, or AGEnTs, a proof of purchase of the product. BE LIABLE To the PurChAsEr or AnY ThIrD PArTY, WhEThEr In What Dimplex will do in the event of a ConTrACT, In TorT, or on AnY defect? oThEr BAsIs, For AnY InDIrECT,...
  • Page 17: Replacement Parts

    Replacement Parts Flicker motor ....... . 2000210300RP heater Assembly ......2203540100RP on/off switch .
  • Page 18: Troubleshooting Guide

    Troubleshooting guide Problem Possible Cause Corrective Action Circuit breaker Improper circuit current Additional appliances may trips or fuse blows rating. exceed the current rating of when unit is turned the circuit breaker or fuse. Plug unit into another outlet or install on a dedicated 15-amp circuit.
  • Page 19 2. If larger glowing sections are causing the heater to trip the thermal cutout, unplug unit, discontinue use and contact technical support. Dimplex North America Limited 1367 Industrial Road Cambridge on Canada n1r 7G8 © 2011 Dimplex north America Limited...

Table of Contents