1-3. TROUBLESHOOTING (Continued)
Problem
Product not done
Unit overheating
(product too dark)
Timers fail to run, or
won't turn off
Timer will not beep

1-4. ERROR CODES

Error Code
"E-6" Prob Err
"E-4" ctrl hot
"E-50" CPU Chip
"E-51" rA-CHIP
"E-53" ro-CHIP
data Err
"E-5" too hot
803
Low or improper voltage
Weak or burnt out elements
Points in contactor bad
Bad relay
Wire(s) loose
Burnt or charred connector
• Probe not properly in position
Check probe calibration
Faulty control board
Check contactor for not
opening
Low voltage
Faulty display board
Indented or torn decal
Faulty speaker
- The control has built-in self-diagnostic error codes that will show on the display .
Cause
Temperature probe failure
Control board temperature too hot
CPU RAM error
External RAM error
External ROM error
Scrambled memory
Software high limit (air temperature
too hot)
Cause
Correction
Use a meter and check the
receptacle against data plate
Check heating element(s) per
Radiant Heaters Section
Check contactor per Contactor
Section
Replace relay per Relays Section
Tighten
Replace wire and clean connectors
Check probe position; see Thermal
Sensor Replacement Section
If probe is more than 10 o F out of
calibration, replace probe
Replace control board per Control
Board Replacement Section
Check for faulty contactor per
Contactor Section
Check voltage at receptacle to
match unit voltage
Check voltage at transformer
Replace display board
Replace control decal
Replace speaker per Speaker
Replacement Section
Correction
Reconnect probe to board, or
replace probe
Replace or clean blower
"E-50", "E-51", "E-53", & "E-41"
are software errors
Reinitialize the board, and if error
persists, replace "E-41" board
Change control board or contactor
Replace blower
SCR-6/8
1-3