Blower Replacement - Henny Penny SCR-6 Technical Manual

Hide thumbs Also See for SCR-6:
Table of Contents

Advertisement

2-4. BLOWER REPLACEMENT

Step 2
Step 3
Step 5
Step 6
Step 7
2-2
1.
Remove electrical power to unit.
To avoid electrical shock or property damage, move
the power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2.
Using Phillips head screwdriver , remove the side panel
closest to the controls.
3.
Remove electrical wires from wire nuts.
4.
Remove discs and rod from inside of unit. (See Cleaning
Section in Operator's Manual.)
5.
Unscrew knob and lift drive-side vent panel up and
out of unit.
6.
Loosen thumb screw and pull out on fan blade and
remove from shaft.
7.
Using a 7/16" nut driver , remove the nuts securing
the blower to the unit, and remove blower from unit.
8.
Replace with new blower in reverse order .
When placing fan blade back onto shaft, rotate fan
blade on the blower shaft, while holding the blower
wheel inside the control area. The fan blade should
snap onto a pin at the base of the shaft.
SCR-6/8