Heat & Glo SL350TRSI-N-CE Owner's Manual page 30

Fireplace
Hide thumbs Also See for SL350TRSI-N-CE:
Table of Contents

Advertisement

Top Vent - Vertical Termination
MODEL
FLUE TERMINATION APPROVALS
SL350TRSI-N-CE
SL350TRSI-PB-CE
This model is approved to use DVP or SLP Series flue
pipe components. A DVP-TVHW or SLP-TVHW vertical
Termination Cap must be used to terminate flue systems
in a vertical position.
Approved flue system components are labeled for identifi-
cation. NO OTHER FLUE SYSTEMS OR COMPONENTS
MAY BE USED. Detailed installation instructions are in-
cluded with each flue termination kit and should be used
in conjunction with this manual.
WARNING! Risk of Fire! This gas appliance and flue
assembly must be flued directly to the outside and must
never be attached to a chimney serving a separate solid
fuel burning appliance. Each gas appliance must use a
separate flue system-common flue systems are prohibited.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping material could ignite and will in-
terfere with proper operation of doors and louvers.
• Horizontal sections 3 inches (7,62 cm) from the top of
the pipe.
• Horizontal sections 2-1/2 inches (6,35 cm) at wall shield
firestops.
• Horizontal sections 1 inches (2,54 cm) from sides and
bottom of the pipe.
• Vertical sections 1 inches (2,54 cm) on all sides of pipe.
Failure to keep insulation or other material away from vent
pipe may cause over heating and fire.
For alternative installations, other than depicted, contact
your dealer for further information.
30
SLP-TVHW, DVP-TVHW
Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. J • 3/13
Straight Up Vertical Flue System
Figure 7.7 shows straight up vertical flue system approved
for use on this model.
If the fireplace installation requires a vertical
flue exceeding 4,5 m above the unit with no
horizontal flue or elbows a vertical flue restric-
tor must be installed (see Figure 7.7).
V
MAX. RUN
36 FT.
(10,97 m)
Figure 7.7
RESTRICTOR
PLATE
Figure 7.8
CAP
V
1