Heat & Glo SL350TRSI-N-CE Owner's Manual page 25

Fireplace
Hide thumbs Also See for SL350TRSI-N-CE:
Table of Contents

Advertisement

C
V
B
J
B
V
V
i
D
V
V
= VENT TERMINAL
A
= 31 cm ......................clearances above grade, veranda,
(See Note 1)
B
= 31 cm ......................clearances to window or door
C
= 46 cm ......................vertical clearance to unventilated
76 cm .......................for vinyl clad soffits and below
D
= 23 cm .....................clearance to outside corner
E
= 15 cm ......................clearance to inside corner
F
= 91 cm ......................not to be installed above a gas
G
= 91 cm ......................clearance to gas service regulator
H
= 31 cm ......................clearance to non-mechanical
(See Note 2)
i
= 1,8 m ......................clearance to a mechanical (pow-
(See Note 2)
** a vent shall not terminate directly above a sidewalk or paved driveway
which is located between two single family dwellings and serves both
dwellings.
*** only permitted if veranda, porch, deck or balcony is fully open on a
minimum of 2 sides beneath the floor, or meets Note 2.
Note 1: On private property where termination is less than 2.1 m above a
sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap
shield is suggested. (See vents components page)
Note 2: Termination in a covered alcove space (spaces open only on one
side and with an overhang) are permitted with the dimensions specified
for vinyl or non-vinyl siding and soffits. 1. There must be .91 m minimum
between termination caps. 2. All mechanical air intakes within 3 m of a
termination cap must be a minimum of .91 m below the termination cap. 3.
All gravity air intakes within .91 m of a termination cap must be a minimum
of .30 m below the termination cap.
Figure 6.3 Minimum Clearances for Termination
E
A
B
V
V
A
X
= AIR SUPPLY INLET
porch, deck or balcony
that may be opened, or to perma-
nently closed window. (Glass)
soffit or to ventilated soffit located
above the terminal
electrical service
meter/regulator assembly within 3
feet (90 cm) horizontally from the
center-line of the regulator
flue outlet
air supply inlet to building or the
combustion air inlet to any other
appliance
ered) air supply inlet
Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. J • 3/13
F
M
G
V
X
H OR i
= AREA WHERE TERMINAL IS NOT PERMITTED
J** = 2,13 m. ................... c l e a r a n c e a b o v e p a v e d
(See Note 1)
K
= 15 cm .................... clearance from sides of electri-
(See Note 5)
L
= 31 cm ..................... clearance above electrical
(See Note 5)
Covered Alcove Applications
M*** = 46 cm ...................clearance under veranda, porch,
107 cm ............ vinyl
N
= 15 cm .............. non-vinyl sidewalls
31 cm .............. vinyl sidewalls
O
= 46 cm .............. non-vinyl soffit and overhang
107 cm ............ vinyl soffit and overhang
P
= 2.4 m
1 cap
2 caps
3 caps
4 caps
Q
= # termination caps x 3 R
MIN
Note 3: Local codes or regulations may require different clearances.
Note 4: Termination caps may be hot. Consider their proximity to
doors or other traffic areas.
Note 5: Location of the vent termination must not interfere with
access to the electrical service.
Vent system termination is NOT permitted in screened porches.
Vent system termination is permitted in porch areas with two or more
sides open. You must follow all side walls, overhang and ground
clearances as stated in the instructions.
Heat & Glo assumes no responsibility for the improper performance
of the appliance when the venting system does not meet these
requirements.
O
N
P
V
R
Q
(See Note 2)
Measure vertical clearances from this surface.
Measure horizontal clearances from this surface.
sidewalk or a paved driveway
located on public property
cal service
service
deck, balcony or overhang
Q
R
MIN
91 cm
2 x Q
1,8 m
1 x Q
2,7 m
2/3 x Q
3,7 m
1/2 x Q
= (2 / # termination caps) x Q
MAX
V
L
K
K
Electrical
V
Service
C
V
MAX
ACTUAL
ACTUAL
ACTUAL
ACTUAL
ACTUAL
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl350trsi-pb-ce

Table of Contents