Key Functions in Panel Test Mode and
Panel Tune Mode
Knob/Key
Test mode
GRP UP
Test mode/Tune mode changeover
GRP DOWN
UP/DOWN
Narrow/Wide changeover
PF1
Frequency CH down
PF2
Frequency CH up
PF3
Signalling CH down
PF4
Signalling CH up
PF5
Not used
Basic function panel
GRP UP
POWER
GRP DOWN
POWER
GRP
TX BUSY
VOL
CH
VOL
UP/DOWN
Full function panel
GRP UP
POWER
GRP DOWN
POWER
CALL
MON
SCAN
GRP
TX
BUSY
VOL
CH
VOL
UP/DOWN PF1
Panel Test Mode
The transceiver's transmission output, receive sensitiv-
ity, and other items are measured and QT, DQT, 2tone and
DTMF signaling is decoded in this mode.
• To enter the panel test mode
Hold down [PF1] and turn the power switch on to enter
this mode. The test frequency channel and test signalling
channel will be displayed.

ADJUSTMENT

Tune mode
Monitor ON/OFF
Tuning item down
TUning item up
Tuning value down
Tuning value up
Tuning value backup
PF1
PF2
PF3
PF4
PF5
MON
SP
OPT
A
B
C
OST
SCN
PF2
PF3
PF4
PF5
TK-790/
Narrow
Test frequency CH
Note : When a key other than GRP down is pressed, the
optional signalling is reset.
• Test frequency channel (MHz)
K : TK-790/(B), 790H(B)
CH
TX
1
161.000
161.100
2
148.000
148.100
3
174.000
173.900
4
161.000
161.000
5
161.200
161.200
6
161.400
161.400
7
• Test signalling channel
CH No.
Encode tone
1
None
2
100Hz square wave
3
QT 67.0Hz
4
QT 151.4Hz
5
QT 250.3Hz
6
DQT 023N
7
Single tone 1633Hz
8
DTMF [9]
9
MSK
Panel Tune Mode
The transceiver is adjusted in this mode.
• To enter the panel tune mode
Press the [GR ] key in the panel test mode.
In this mode, QT and DQT signalling is decoded, but
2tone and DTMF signalling is not decoded.
The adjustment items, the frequency and signalling,
other than the maximum deviation and sensitivity, return to
the values that were effective for the test frequency chan-
nel and test signalling channel before entering the panel
tune mode.
(
B
)
/H
(
Test signalling CH
K2 : TK-790(B)
RX
TX
RX
146.000
146.100
136.000
136.100
156.000
155.900
146.000
146.000
146.200
146.200
146.400
146.400
162.000
161.900
Decode tone
None
None
QT 67.0Hz
QT 151.4Hz
QT 250.3Hz
DQT 023N
2 tone 321.7/928.1Hz
DTMF [159]
None
B
)