5. MAINTENANCE AND ADJUSTMENT :
@ COVER
REMOVAL
@ LITHIUM
BATTERY
M@ MICROCOMPUTER
RESET
18
1
Loosen
5 screws (¢2.6x 5 mm) of the side
panels
2
To remove
the top cover, remove
2 screws
{¢2.6x 5 mm)
Tee Ree
3
To
remove
the
bottom
cover,
remove
5
Loosen
screws (62.6 x5
mm).
Adjust VR1 on unit B (X53-1340-11/61) to the desired level.
7
|__- Reset opening
A lithium battery is contained in the transceiver to retain memory.
Therefore,
turning off the POWER
switch, disconnecting
the power cable, or a power
failure will not clear the memory.
The
battery will last approximately
five
years. When the battery discharges an erroneous display may appear on the
LCD.
Lithium battery replacement should be performed by an authorized TRIO-
KENWOOD
service facility either your TRIO-KENWOOD
dealer, or the factory
Note:
When the lithium battery is replaced, the microprocessor must be reset.
Note:
Removing
the
battery
does
not
require
reprogramming
the
operating
system, only your memory channel information etc.
Depress the reset switch with a nonconductive rod, through the reset opening
of the bottom cover as shown