IBM NetVista N2800e Reference Manual page 57

Ibm net vista thin client express reference manual
Table of Contents

Advertisement

Exchanging the memory
See "Resolving hardware problems" on page 31 to
determine whether or not it is necessary to replace the logic
unit, or any other parts. For information on ordering thin
client hardware parts, refer to "Replacing parts other than
the N2800e CompactFlash card" on page 42. Complete the
procedure, "Removing the logic unit to install parts" on
page 45 before performing the following Dual Inline
Memory Module (DIMM) procedures:
1. To remove a DIMM from the logic unit, press the two
tabs B located at each end of the DIMM A out and
down.
2. To install a DIMM into the logic unit, align the notches
on the bottom of the DIMM A with the notched areas
on the memory socket.
3. Press down firmly on the center of DIMM A until the
memory socket tabs B flip up.
4. See "Reassembling the thin client" on page 45.
Exchanging the lithium battery
Read "Caution notices" on page vi, and see "Removing the
logic unit to install parts" on page 45 before continuing.
1. To remove the battery, place your thumb on the battery
C and lift it up with your index finger.
2. Dispose of the used battery according to your local
regulations.
3. Install the new battery into the battery socket D , with
the "+" sign facing up.
4. See "Reassembling the thin client" on page 45.
Note: If you receive an error message on your screen after
performing this procedure, see "Resolving hardware
problems" on page 31.
Appendix B. Hardware maintenance procedures
47