Carrier 59SP5A Installation, Start-Up, Operating And Service And Maintenance Instructions page 18

Series 100 single stage 4-way multipoise gas furnace
Table of Contents

Advertisement

CAUTION
!
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care
and wear appropriate protective clothing, safety glasses and
gloves when handling parts, and servicing furnaces.
Fig. 12 - - Knockout Removal
Fig. 13 - - Example of Field Drain Attachment
A11305
OPEN STAND
PIPE FOR
A/C OR
HUMIDIFIER
DRAIN
TEE
TO OPEN
DRAIN
A11276
18
INSTALL CLAMPS ON DRAIN TUBE
ATTACH DRAIN TUBE TO CONDENSATE
DRAIN TRAP
PULL DRAIN STUB
THROUGH CASING
Fig. 14 - - Formed Tube Grommet
Cut and remove formed end of
drain tube for left side and horizontal
drain connection
RIGHT SIDE DRAIN ELBOW
Fig. 15 - - Modify Drain Tube
A11342
A11388