Manual Test; Timed Test - 10 Minutes - Cleveland SteamCraft V Service Manual

Counter type convection steamer
Table of Contents

Advertisement

MANUAL Test

1. If not already done, perform SETUP.
2. Activate the manual cooking cycle by pressing the MANUAL touch pad
(2).
• The heater elements and the cold water condenser will turn on.
• If no TIMED or MANUAL tests have been done, it will take
approximately two minutes for the water in the steam generator to
reach operating temperature and begin generating steam
3. Open the steamer door. The compartment should be filled with steam.
• When the door is opened, the heating elements mm off. The steam
should dear from the compartment quickly.
4. When the steam has cleared from the compartment, close the steamer
door.
• The heater elements and the cold water condenser win turn on, and
start generating steam.
5. Open the steamer door. The compartment should again be filled with
steam.
6. It necessary, repeat this test to be sure the steam shuts off when the
door opens and restarts when the door closes.

TIMED Test - 10 Minutes

1. If not already done, perform SETUP.
2. Refer to figure 2-22, and set the TIME DISPLAY (9) to 10 minutes by
pressing the TIME SET 10 minute touch pad (4) once.
3. Start the timed cooking sequence by pressing the TIMED touch pad
(6).
• If no TIMED or MANUAL tests have been done, it will take
approximately two minutes for the water in the steam generator to
reach operating temperature and begin generating steam.
• The timer counts down to 00 and an alarm beeps four times.
4. When the alarm beeps four times, refer to figure 2-21, and open the
drain valve. Measure the temperature of the drain water. It should be
between 150° and 170°.
CET-16 Service Manual
Page 23
Printed 4/90