Carrier WEATHERMASTER 50HJQ004-016 Product Data page 57

Single-package rooftop standard and high efficiency units 3 to 15 nominal tons
Hide thumbs Also See for WEATHERMASTER 50HJQ004-016:
Table of Contents

Advertisement

UNIT
50TFQ
1
0
/
2
004†
1000
976
004**
1455
1423
005†
1175
1135
005**
1455
1423
006†
1192
1166
006**
1685
1647
007††
1460
1420
007**
1685
1647
008††
840
815
008***
935
910
008**
1080
1025
009††
935
910
009**
1080
1025
012††
935
910
012†
1085
1060
012**
1130
1112
*Approximate fan rpm shown.
†Indicates alternate motor and drive package.
**Indicates high-static motor and drive package.
ACCESSORY/HEATER STATIC PRESSURE* (in. wg) — 50TFQ004-007
COMPONENT
1 Heater Module
2 Heater Modules
*The static pressure must be added to external static pressure. The sum and the evaporator
entering-air cfm should then be used in conjunction with the Fan Performance tables to deter-
mine blower rpm and watts.
ACCESSORY/HEATER STATIC PRESSURE* (in. wg) — 50TFQ008-012
COMPONENT
2250
1 Heater Module
2 Heater Modules
*The static pressure must be added to external static pressure. The sum and the evaporator
entering-air cfm should then be used in conjunction with the Fan Performance tables to deter-
mine blower rpm and watts.
COMPONENT
Vertical EconoMi$er IV and EconoMi$er2
Horizontal EconoMi$er IV and
EconoMi$er2
LEGEND
FIOP — Factory-Installed Option
COMPONENT
Vertical EconoMi$er IV and EconoMi$er2
Horizontal EconoMi$er IV and EconoMi$er2
LEGEND
FIOP — Factory-Installed Option
FAN RPM AT MOTOR PULLEY SETTINGS* — 50TFQ004-012
1
1
1
/
2
2
952
928
904
1392
1360
1328
1094
1054
1013
1392
1360
1328
1140
1114
1087
1608
1570
1531
1380
1345
1305
1608
1570
1531
790
765
740
885
860
835
1007
988
970
885
860
835
1007
988
970
885
860
835
1035
1010
985
1087
1062
1037
900
1200
1400
0.05
0.07
0.09
0.15
0.16
0.16
2500
3000
0.02
0.03
0.05
0.03
0.05
0.07
ACCESSORY/FIOP STATIC PRESSURE* (in wg) — 50TFQ004-007
1250
0.045
ACCESSORY/FIOP STATIC PRESSURE* (in wg) — 50TFQ008-012
2250 2500
0.06 0.075
0.1
MOTOR PULLEY TURNS OPEN
1
1
2
/
3
3
/
2
2
880
856
832
1297
1265
1233
973
932
892
1297
1265
1233
1061
1035
1009
1493
1454
1416
1265
1225
1185
1493
1454
1416
715
690
665
810
785
760
952
933
915
810
785
760
952
933
915
810
785
760
960
935
910
1012
987
962
††Indicates standard motor and drive package.
***Indicates alternate drive package only.
CFM
1600
1800
2000
0.09
0.10
0.11
0.16
0.17
0.17
CFM
3500
4000
4500
0.07
0.08
0.10
0.09
0.12
0.14
1500
1750
2000
0.065
0.08
0.12
0.1
0.125
*The static pressure must be added to external static pressure. The
sum and the evaporator entering-air cfm should then be used in con-
junction with the Fan Performance tables to determine blower rpm and
watts.
2750
3000 3250 3500 3750 4000 4250 4500 4750
0.09
0.115 0.13
0.15
0.17 0.195 0.22
0.125
0.15
0.18
0.21
0.25 0.275
*The static pressure must be added to external static pressure. The
sum and the evaporator entering-air cfm should then be used in con-
junction with the Fan Performance tables to determine blower rpm and
watts.
1
4
4
/
5
2
808
784
760
1202
1170
1138
851
811
770
1202
1170
1138
983
957
930
1377
1339
1300
1150
1110
1070
1377
1339
1300
635
615
590
735
710
685
897
878
860
735
710
685
897
878
860
735
710
685
885
860
835
937
912
887
2200
2400
0.11
0.12
0.17
0.18
5000
5500
0.12
0.14
0.16
0.19
CFM
2250
2500
0.145
0.175
0.15
0.18
CFM
0.25 0.285 0.325 0.36
0.3
0.34 0.388
1
5
/
6
2
1107
1075
1107
1075
904
878
862
830
2600
3000
0.13
0.15
0.18
0.19
6000
6250
0.16
0.17
0.21
0.20
2750
3000
0.22
0.255
0.225
0.275
5000 5250 6250