Performance data — 50HJQ (cont)
50HJQ014 (208/230 V AND 460 V) (12
Airflow
0.2
(Cfm)
Rpm
Watts
3750
724
481
4000
754
613
4250
786
757
4500
818
914
4750
850
1084
5000
883
1267
5250
917
1464
5500
950
1675
5750
985
1901
6000
1020
2142
6250
1055
2398
50HJQ014 (208/230 V AND 460 V) (12
Airflow
1.2
(Cfm)
Rpm
Watts
3750
1190
1526
4000
1208
1684
4250
1227
1853
4500
1247
2036
4750
1269
2232
5000
1291
2441
5250
1315
2664
5500
1339
2900
5750
1364
3151
6000
1389
3416
6250
1415
3695
LEGEND
Bhp
— Brake Horsepower Input to Fan
FIOP
— Factory-Installed Option
Watts — Input Watts to Motor
*Standard drive range is 891 to 1179 rpm. Alternate drive range is 1227 to 1559.
Other rpms may require a field-supplied drive.
50HJQ014 (575 V) (12
1
/
TONS)*
2
Airflow
0.2
(Cfm)
Rpm
Watts
3750
724
481
4000
754
613
4250
786
757
4500
818
914
4750
850
1084
5000
883
1267
5250
917
1464
5500
950
1675
5750
985
1901
6000
1020
2142
6250
1055
2398
50HJQ014 (575 V) (12
1
/
TONS)* (cont)
2
Airflow
1.2
(Cfm)
Rpm
Watts
3750
1190
1526
4000
1208
1684
4250
1227
1853
4500
1247
2036
4750
1269
2232
5000
1291
2441
5250
1315
2664
5500
1339
2900
5750
6000
6250
LEGEND
Bhp
— Brake Horsepower Input to Fan
FIOP
— Factory-Installed Option
Watts — Input Watts to Motor
*Factory-shipped motor drive range is 1159 to 1429 rpm. Other rpms may require
a field-supplied drive.
112
FAN PERFORMANCE — VERTICAL DISCHARGE UNITS (cont)
1
/
TONS)*
2
0.4
Bhp
Rpm
Watts
Bhp
0.55
838
685
0.78
0.70
865
824
0.94
0.86
893
975
1.11
1.04
922
1138
1.30
1.23
951
1313
1.50
1.44
980
1501
1.71
1.67
1011
1703
1.94
1.91
1041
1918
2.19
2.17
1072
2147
2.45
2.44
1103
2391
2.72
2.73
1135
2650
3.02
1
/
TONS)* (cont)
2
1.4
Bhp
Rpm
Watts
Bhp
1.74
1265
1746
1.99
1.92
1281
1908
2.17
2.11
1299
2082
2.37
2.32
1317
2268
2.58
2.54
1337
2468
2.81
2.78
1358
2680
3.05
3.03
1380
2907
3.31
3.30
1403
3148
3.59
3.59
1426
3403
3.88
3.89
1450
3672
4.18
4.21
0.4
Bhp
Rpm
Watts
Bhp
0.55
838
685
0.78
0.70
865
824
0.94
0.86
893
975
1.11
1.04
922
1138
1.30
1.23
951
1313
1.50
1.44
980
1501
1.71
1.67
1011
1703
1.94
1.91
1041
1918
2.19
2.17
1072
2147
2.45
2.44
1103
2391
2.72
2.73
1135
2650
3.02
1.4
Bhp
Rpm
Watts
Bhp
1.74
1265
1746
1.99
1.92
1281
1908
2.17
2.11
1299
2082
2.37
2.32
1317
2268
2.58
2.54
1337
2468
2.81
2.78
1358
2680
3.05
3.03
1380
2907
3.31
3.30
External Static Pressure (in. wg)
0.6
Rpm
Watts
Bhp
Rpm
937
889
1.01
1028
962
1034
1.18
1050
987
1191
1.36
1073
1013
1360
1.55
1097
1040
1541
1.76
1122
1068
1736
1.98
1147
1096
1943
2.21
1174
1124
2165
2.47
1201
1153
2400
2.73
1228
1183
2649
3.02
1256
1213
2912
3.32
1284
External Static Pressure (in. wg)
1.6
Rpm
Watts
Bhp
Rpm
1337
1972
2.25
1405
1351
2136
2.43
1418
1367
2313
2.64
1433
1384
2503
2.85
1448
1403
2707
3.08
1465
1422
2923
3.33
1484
1443
3154
3.59
1503
1464
3398
3.87
1524
1486
3657
4.17
NOTES:
1. Maximum continuous bhp is 4.25 and maximum continuous watts are 3775.
Do not adjust motor rpm such that motor maximum bhp and/or watts is
exceeded at the maximum operating cfm.
2. Fan performance is identical for horizontal discharge applications using hor-
izontal adapter curb (CRRFCURB013A00).
3. See page 113 for General Fan Performance notes.
External Static Pressure (in. wg)
0.6
Rpm
Watts
Bhp
Rpm
937
889
1.01
1028
962
1034
1.18
1050
987
1191
1.36
1073
1013
1360
1.55
1097
1040
1541
1.76
1122
1068
1736
1.98
1147
1096
1943
2.21
1174
1124
2165
2.47
1201
1153
2400
2.73
1228
1183
2649
3.02
1256
1213
2912
3.32
External Static Pressure (in. wg)
1.6
Rpm
Watts
Bhp
Rpm
1337
1972
2.25
1405
1351
2136
2.43
1418
1367
2313
2.64
1433
1384
2503
2.85
1448
1403
2707
3.08
1465
1422
2923
3.33
NOTES:
1. Maximum continuous bhp is 3.45 and maximum continuous watts are 3065.
Do not adjust motor rpm such that motor maximum bhp and/or watts is
exceeded at the maximum operating cfm.
2. Fan performance is identical for horizontal discharge applications using hor-
izontal adapter curb (CRRFCURB013A00).
3. See page 113 for General Fan Performance notes.
0.8
Watts
Bhp
Rpm
1097
1.25
1111
1247
1.42
1131
1408
1.60
1152
1583
1.80
1174
1770
2.02
1197
1969
2.24
1221
2183
2.49
1246
2409
2.75
1272
2650
3.02
1298
2905
3.31
1324
3175
3.62
1352
1.8
Watts
Bhp
Rpm
2199
2.51
1471
2368
2.70
1483
2548
2.90
1496
2742
3.12
1510
2948
3.36
1526
3168
3.61
1544
3403
3.88
1562
3651
4.16
0.8
Watts
Bhp
Rpm
1097
1.25
1111
1247
1.42
1131
1408
1.60
1152
1583
1.80
1174
1770
2.02
1197
1969
2.24
1221
2183
2.49
1246
2409
2.75
1272
2650
3.02
1298
2905
3.31
1.8
Watts
Bhp
Rpm
2199
2.51
1471
2368
2.70
1483
2548
2.90
1496
2742
3.12
1510
2948
3.36
1.0
Watts
Bhp
1309
1.49
1463
1.67
1629
1.86
1808
2.06
2000
2.28
2204
2.51
2423
2.76
2655
3.02
2901
3.31
3160
3.60
3435
3.91
2.0
Watts
Bhp
2431
2.77
2603
2.97
2787
3.18
2983
3.40
3194
3.64
3418
3.89
3655
4.16
1.0
Watts
Bhp
1309
1.49
1463
1.67
1629
1.86
1808
2.06
2000
2.28
2204
2.51
2423
2.76
2655
3.02
2901
3.31
2.0
Watts
Bhp
2431
2.77
2603
2.97
2787
3.18
2983
3.40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents