f f e e a a t t u u r r e e s s m m e e n n u u
The factory default settings are indicated in b b o o l l d d text in the table below.
F F E E A A T T U U R R E E
D D E E F F A A U U L L T T - - L L E E D D O O N N S S E E T T T T I I N N G G
N N U U M M B B E E R R
( ( P P R R E E S S S S C C H H A A N N N N E E L L 1 1 ) )
1
E E n n g g i i n n e e c c h h e e c c k k i i n n g g o o n n
T T a a c c h h o o m m e e t t e e r r c c h h e e c c k k i i n n g g t t y y p p e e
2
3
1 1 2 2 m m i i n n u u t t e e s s r r u u n n t t i i m m e e (1)* *
4
F F l l a a s s h h i i n n g g p p a a r r k k i i n n g g l l i i g g h h t t o o u u t t p p u u t t
5
C C r r a a n n k k i i n n g g t t i i m m e e 0 0 . . 6 6 s s e e c c . . (1)
V V o o l l t t a a g g e e c c h h e e c c k k h h i i g g h h l l e e v v e e l l
6
7
S S h h o o r r t t R R u u n n ( ( t t u u r r b b o o t t i i m m e e r r ) ) : : 1 1 (1) m m i i n n
8
Activation pulse: 1 (1)
9
I I g g n n i i t t i i o o n n / / a a c c c c e e s s s s o o r r y y o o u u t t p p u u t t : : I I g g n n i i t t i i o o n n
10
A A c c c c e e s s s s o o r r y y s s t t a a t t e e d d u u r r i i n n g g w w a a i i t t t t o o s s t t a a r r t t : : O O F F F F
2 2 n n d d s s t t a a t t u u s s o o u u t t p p u u t t : : N N o o r r m m a a l l (1)
11
12
D D i i e e s s e e l l t t i i m m e e r r W W a a i i t t - - t t o o - - S S t t a a r r t t i i n n p p u u t t (1)
13
R R u u n n T T i i m m e e ( ( T T i i m m e e r r M M o o d d e e ) ) 1 1 2 2 m m i i n n u u t t e e s s (1)
14
D D o o o o r r L L o o c c k k p p u u l l s s e e d d u u r r a a t t i i o o n n 0 0 . . 8 8 s s e e c c o o n n d d s s (1) 3.5 (2), 0.4 (3) seconds
U U n n l l o o c c k k o o u u t t p p u u t t 1 1 p p u u l l s s e e
15
16
L L o o c c k k o o u u t t p p u u t t 1 1 p p u u l l s s e e
I I g g n n i i t t i i o o n n u u n n l l o o c c k k O O N N
17
18
I I g g n n i i t t i i o o n n l l o o c c k k O O N N
19
F F a a c c t t o o r r y y A A l l a a r r m m D D i i s s a a r r m m f f u u n n c c t t i i o o n n w w i i t t h h u u n n l l o o c c k k Before Unlock (2)/Remote Start only (3)
20
F F a a c c t t o o r r y y A A l l a a r r m m D D i i s s a a r r m m 1 1 p p u u l l s s e e
21
Comfort Closure ON
* * N N O O T T E E : : The number in parentheses indicate the number of times the LED will flash
© 2005 Directed Electronics—all rights reserved
L L E E D D O O F F F F S S E E T T T T I I N N G G
( ( P P R R E E S S S S C C H H A A N N N N E E L L 2 2 ) )
Engine checking off
Voltage checking type
24 minutes (2)*, 60 minutes (3) run time
Constant parking light output
Cranking time 0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5),
1.6 (6), 1.8 (7), 2.0 (8), 4.0 (9) sec.
Voltage check low level
Short Run (turbo timer) 3 (2), 5 (3), 10 (4) min.
A A c c t t i i v v a a t t i i o o n n p p u u l l s s e e s s : : 2 2 (2), 3 (3)
Ignition/accessory output: Accessory
Accessory state during wait to start: ON
Rear defogger latched (2)/pulsed (3)
Timed 15 (2), 30 (3), 45 (4) seconds
3 (2), 6 (3), 9 (4) minutes
Unlock output 2 pulses
Lock output 2 pulses
Ignition unlock OFF
Ignition lock OFF
2 pulses
O O F F F F
2 2 7 7