INTELIA
7.14. Boiler
Release the boiler cover
and take it off.
7.15. Dispenser assembly
Loosen the screws as illustrated and remove the front panel to
access the screws which fi x the dispenser cover into place.
7.16. Valve disassembly
A
Loosen the screws as
illustrated and remove the
boiler pin (A)
Saeco International Group
Unscrew the marked screw and disconnect the
electrical and water circuit connections.
Press the hooks as illustrated and slide out the dispenser assembly.
Loosen the screws as illustrated and remove the front panel to
access the screws which fi x the dispenser cover into place
Rev. 03
07 DISASSEMBLY
Slide out the fork as illustrated.
Page