INTELIA
Level 2 (switch) [LED No Water + Error ON]
Description:
Verify the security switch connection
Action:
Mechanical move the switch and verify the relative electrical feedback
Start condition (no water tank, no BU, no dump box, door open)
All LED are blinking (because every switch is OFF)
Closing every switch turns ON the LED
Switch
Water presence
BU presence
Door open
Dump box
On ERROR verify:
Cable connection
Power supply
Level 3 (Aroma trimmer) [LED No Water + Error + Double ON]
Description:
Verify the aroma trimmer
Action:
Rotate aroma trimmer, 3 position 3 LED
Start condition none
Aroma
LED
1 bean
hot water
2 beans
hot water + espresso
3 beans
hot water + espresso + coffee
On ERROR verify:
Cable connection
Power supply
Saeco International Group
LED
hot water
espresso
coffee
steam
Press ON/OFF button moves to next level
Press ON/OFF button moves to next level
Rev. 03